Silverton Solar - Pty Ltd

Silverton Solar - Pty Ltd PV Solutions by a Electrical Engineer that has created custom Solar solutions and designs since 2007. Grid-tie, off-grid, Hybrid and UPS designs

Panels, Inverters, charge controllers, batteries and complete solar solutions. Nico started with a great interest in renewable energy, perhaps due to his engineering background. After seeing many failed installations he had a need to find out what made the design's complex or prone to failure. As he perfected his design's, along-the-way teaching some distributers a thing or two, so the technology also matured. Silverton Solar was born as a parnership between Nico and Heinrich (a IT Consultant) due to the need to integrate Solar technology into IT networks. If you own a Solar installation then you need to know how much energy is being generated and consumed as well as be able to see indicators of Solar generation no longer being optimal. If required, we could integrate monitoring technologies into your home or business IT network and even monitor it on your behalf. One of our products, Solar Edge, even has cellular apps to remotely monitor your Solar performance in real-time. Silverton Solar has a firm belief that you cannot Quality Assure your own work, therefore our installation team is being quality assured by a different person that is not part of the same team. When the installation is completed we do not walk away, we test and check everything and even re-check after a week or two to ensure complete stability and ease of mind.

12/06/2025

It’s interesting how both clients and some installers are pushing for communication between batteries and inverters, thinking it’s always a benefit. But in reality, it can create system instability.

This is likely driven by the need to understand how full a battery is, the human mind understands percentages a lot better than trying to learn that at xV my battery is empty and at yV it is full.

Let’s say you use SOC (State of Charge) to set your battery's lower discharge limit. The minimum safe voltage for a typical lithium iron phosphate (LiFePO₄) cell is around 3.0V, so for a 16-cell battery (16s), that equates to 48V.

However, SOC and voltage do not have a linear relationship, especially on lithium batteries. What would the voltage be if you discharged to 20% State of Charge (SOC)? You can’t say with certainty. Lithium batteries "flatten" their voltage curve across most of their SOC range. Voltage doesn’t drop steadily from 100% to 0%. Instead, most voltage drop happens rapidly near the bottom 10–20% and the top 5–10%. This makes voltage an unreliable indicator for precise SOC measurement.

More importantly, SOC is a calculated value, not directly measured. It only becomes reasonably accurate if the battery is left idle for several hours. On a solar system, this rarely happens. That’s why we prefer voltage-based cutoffs for system settings. It’s more consistent and safer.

Real-World Example:

We recently tested a popular battery brand paired with a Sunsynk inverter. When enabling CAN communication between them, the battery was overcharged by more than 1V. And we hadn’t changed anything except enabling communication!

Using Swift, our monitoring platform, we could clearly compare the BMS voltage with the inverter-reported voltage. The discrepancy was obvious and significant. That kind of overvoltage can void the battery’s warranty. How is that fair to the client?

More Supporting Data:

Three batteries, identical models, about 9 months old:
Battery 1: 50.17V, 12.02% SOC
Battery 2: 50.30V, 9.79% SOC
Battery 3: 50.60V, 27.53% SOC
(Bus bars were in place, and cable lengths and thickness were verified.)

A six-battery system, different brand. All report 53.4 or 53.5V, but SOC varies from 44% to 95%.

Another system with three batteries shows SOC differences between 70% and 74%, even though the voltages are identical.
(Not dramatic, but still relevant if the system relies on SOC.)

Takeaway:

Just because I have this data does not mean your system definitely has the issue. But here’s a useful clue: if your battery LEDs (those little lights on the front) are often out of sync, for example, one showing 3 lights and another showing 4, it might be a sign of imbalance or communication mismatch.

25/06/2024

Got great news today. We now have a Solar financing option that will allow our clients to pay for their system from their saving, and likely have a few bucks to spare!

Some people feel that there is no need to install Solar with loadshedding in the past.
1) We are also positive about the countries long term energy generation
2) For some time to come breakdowns will still affect us
3) As eskom price adjustments happen a system will create bigger and better savings for those investing in the technology

Our systems are designed by an electrical engineer. We often implement new standards before it becomes legislation. Our systems are quality assured by a separate team member.

Try us for fair pricing and ethical, standards based, installations.

Heinrich 010 065 0430
Nico

Address

Pretoria
0181

Opening Hours

Monday 08:00 - 17:00
Tuesday 08:00 - 17:00
Wednesday 08:00 - 17:00
Thursday 08:00 - 17:00
Friday 09:00 - 16:00
Saturday 09:00 - 12:00

Telephone

+27100650430

Alerts

Be the first to know and let us send you an email when Silverton Solar - Pty Ltd posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Silverton Solar - Pty Ltd:

Shortcuts

Share