A large number of automatic borehole filter heads are backwashing in the dark. Badly.
Two in the morning is when the heads are timed to run their clean cycle. Sensible enough: shutting off supply in daylight means your taps go dry. Nobody wants that conversation before coffee.
Here is the problem nobody tells you.
At two in the morning, your tanks are full. Full tanks mean the float switch has already told the borehole controller to rest. Borehole controller resting means no water is moving through the vessels. And a backwash with no water passing through it is just a cycle. A performance. Nothing gets cleaned.
The filter head is doing its job. The borehole controller is doing its job. They just have no idea the other one exists.
There is a communication cable for exactly this reason. It tells the borehole controller: ignore the float switch for now, I need you on so I can flush. Without it wired in, the two systems spend every night politely not talking to each other while your filtration media quietly stops working.
What you get is a vessel that looks fine, reads fine, and filters less with every passing month. No alarm. No obvious symptom. Just gradually worse water from a system you were told was sorted.
The cable costs very little. The conversation it starts, at two in the morning, between two components that never meet, is the only reason the system actually does what it was sold to do.
Silence between machines is not peace. It is just a problem nobody has noticed yet.
Andy Plumbers. Installing Happiness.