Controlpro Electrical

Controlpro Electrical Accredited electrician for single & three phase installation work ie:- Domestic-industrial-motor control etc ,all areas .

Latest project finished Northlink campus Wingfield,comprised of lecture rooms & workshops plus  120mm main feeder cable,...
23/07/2018

Latest project finished Northlink campus Wingfield,comprised of lecture rooms & workshops plus 120mm main feeder cable, (tough pulling that one in 192 meters).

19/02/2018
19/02/2018
13/02/2018

With the current water crisis people are installing boreholes / wellpoints, the electrical circuit for these can be as follows :-
* Main DB in house circuit on E/leakage unit with an isolator adjacent to pump .
* Pool pump DB on E/leakage unit with any of the following provisions :-
1 - If DB or disconnector not in line of sight , must be lockable in the off position .
2 - Isolator adjacent to pump.
3 - Socket outlet adjacent to pump.
* Regarding the wiring therof I personally prefer the following methods :-
1 - 2,5mm armoured cable installed on surface ie ;- wall or in ground 500mm deep.
2 - 2,5mm surfix / twin&earth cable or GP wires in a conduit installed on surface or in ground 500mm deep / just under paving is also ok .
3 - 2,5mm surfix in ground or surface , but protected with conduit etc where damage may occur.

* NOTE * do not connect it to the nearest lighting circuit because it may be easier to get too.

08/01/2018

Still on the topic with regard to the issue of an Electrical C.o.C....The electrician will first perform an inspection of the premises , this involves an inspection fee to be payed regardless of outcome , if the premises are up to regulation a C.o.C can be issued.
If any items are found to be not to regulation,this will be priced out separate to the inspection fee , if at this point you reject the quote & call in another electrical contractor ,the whole process starts again & you will be recharged accordingly .

27/11/2017

When asking for a C.o.C to be issued for your premises electrical system , it is important to note that it doe`s not cover the following :-
* The appliance itself ie : Stove - Geyser element/thermostat etc.
*Light fittings - Globes .
*Pool pump-Borehole pump-Gate/garage motors.
# Only the EARTHING aspect thereof.
*It essentially covers the DB panel , socket outlets
,light switches , isolators & the wiring up to said appliances and is deemed to be ELECTRICALLY SAFE .
* Having said that the wiring codes are a bit ambiguous and open to different interpretations & most estate agents will require you to fix faulty items as a prerequisite to selling , the C.o.C issuing electrician will also like relevant items fixed to avoid unnessary comebacks & conflict.

20/11/2017

To better understand your electricity bill,you are charged per Kwhr ( kilowatt hour is 1000 watts ) example :- if your 1 Kw pool pump runs for 1 hour thats 1 x Kwhr / unit . so if your pump runs for 6 hours a day for 30 days = 180 Kwhr / units at the applicable Eskom rate & levies.

13/11/2017

Don`t pull your appliances out by the cord , this will damage the outlet over time , also best to switch it off first to prevent any Arcing.

31/10/2017

Check all your extension cords for damage periodically , if a fault occurs the resultant surge can blow sensitive equipment, repair or replace .

23/10/2017

If you still have filament / halogen globes on a dimmer switch and thinking of upgrading to LED , your dimmer module will most likely be incompatible ( doing it own thing ) you will need to get them replaced - also ensure globes are dimmable .

09/10/2017

Regarding your wall socket outlets,try not to use extender multi plug units as these can lead to overloading & possible fire hazard, if you do buy get the better ones which include a trip or circuit breaker .

27/09/2017

Test your earth leakage unit often by pushing the test button ( just make sure you have nothing important running ie:- computor etc ) if it fails to trip get it replaced ASAP this device can save you & your families life .