27/08/2026
Three methods. One location. Zero guesswork.
Another client in Wetton was losing a serious amount of water in a matter of days.
Again, we ran a pressure test on the jet line first.
Start: 0.24 Bar. End: 0.04 Bar.
A significant drop. Something was wrong.
The skimmer line held steady. Then we brought out the tracer gas. We swept the paved area next to the pool and got a detection close to the skimmer box. That pinpointed the general zone.
Acoustic testing confirmed it. Positive frequency change, right where the gas had pointed.
We ran a dye test directly on the jet line. Dye loss noted.
Three separate methods pointing to the same location.
Our recommendation: open the paving, excavate, expose the jet line, repair it, pressure test to confirm. As NSPI members we do a proper job; not just a fix and cover-up.
Want to be 100% sure before digging? Talk to our team.
π 021 200 5887
βοΈ [email protected]