Critical Heating & Hydronics LLC

Call Directions Website

Critical Heating & Hydronics LLC We are a fully insured, heating and hydronics company located in Rochester New York.

🔥 DON’T WAIT UNTIL THE LAST MINUTE! 🔥The first cold night is NOT the time to find out your boiler or furnace has a probl...
10/05/2026

🔥 DON’T WAIT UNTIL THE LAST MINUTE! 🔥

The first cold night is NOT the time to find out your boiler or furnace has a problem.

Today’s inspection is a perfect example. We found a safety issue serious enough that the appliance had to be red-tagged and taken out of service. That’s exactly why having your heating equipment inspected before you need it matters.

A proper inspection can catch combustion, venting, safety, control, and mechanical issues before they become an emergency.

Don’t wait for the first cold night. Get your heating equipment checked now.

Critical Heating & Hydronics LLC
Heating • Hydronics • HVAC

Preventive maintenance saves money, prevents breakdowns, and keeps your system running when you need it most. Give us a ...
10/04/2026

Preventive maintenance saves money, prevents breakdowns, and keeps your system running when you need it most. Give us a call and schedule your appointment today!

🔥 Wireless Thermostat Installation — No Walls to Open!Another thermostat upgrade completed by Critical Heating & Hydroni...
10/03/2026

🔥 Wireless Thermostat Installation — No Walls to Open!

Another thermostat upgrade completed by Critical Heating & Hydronics LLC!

This is a really old home with traditional lath-and-plaster walls, making it extremely difficult to run new thermostat wiring without opening up the walls and potentially causing unnecessary damage.

Instead of cutting into the walls, we installed a Braeburn BlueLink 8500 wireless thermostat and control module, integrating it with the existing Taco zone control for the hydronic gas boiler system.

A clean solution that gives the homeowner modern thermostat control without tearing into the original walls.

🔧 Installation included:

* Braeburn BlueLink 8500 wireless thermostat
* Wireless control module
* Integration with existing Taco zone control
* Existing hydronic gas boiler system
* No wall demolition or new thermostat wiring required

Sometimes the best installation is the one that doesn’t require opening the walls. 🔥

Critical Heating & Hydronics LLC
Heating • Hydronics • HVAC

09/30/2026

🔥 Heating Season Is Here — Is Your System Ready? 🔥

As temperatures begin to drop and heating systems start running more frequently, now is the time to make sure your heating equipment is properly serviced, inspected, and operating safely.

Don’t wait until the first major cold snap—or until your heating system stops working—to find out there’s a problem.

⚠️ Carbon monoxide (CO) poisoning is preventable.

Carbon monoxide is an odorless, colorless, and potentially deadly gas produced when fuels such as natural gas, propane, oil, wood, and other fuels do not burn properly. Heating equipment, fireplaces, generators, vehicles, and other fuel-burning appliances can all be sources of CO.

During the winter months, heating systems may run for hours at a time, increasing the importance of proper maintenance, ventilation, and working carbon monoxide detectors.

Know the symptoms of CO poisoning:
• Headache
• Dizziness
• Weakness
• Nausea or vomiting
• Chest pain
• Confusion

Make sure you have working CO detectors near sleeping areas, never operate fuel-burning equipment in an enclosed or improperly ventilated space, and have your heating equipment inspected and maintained by a qualified professional.

🏠 A little preventative maintenance can help keep your family warm and safe all winter long.

If your heating system hasn’t been serviced yet, now is the time to schedule it.

Critical Heating & Hydronics LLC
Keeping you comfortable. Keeping you safe.

Another exhaust fan brought into the Siemens BMS.Wired the exhaust fan into the Siemens control system, programmed the V...
09/28/2026

Another exhaust fan brought into the Siemens BMS.

Wired the exhaust fan into the Siemens control system, programmed the VFD and set all operating parameters, configured and verified the control points, and built the graphics for complete BAS monitoring and control.

From field wiring → VFD programming → parameter setup → Siemens I/O → point configuration → graphics — taking an older piece of equipment and bringing the entire system into modern BAS control.

Another full controls integration from the equipment all the way back to the BMS.

Upgraded the standard anode rod to a powered anode rod on the power-vented water heater to provide enhanced corrosion pr...
09/01/2026

Upgraded the standard anode rod to a powered anode rod on the power-vented water heater to provide enhanced corrosion protection and extend the life of the unit.

Performed a preventative flush of the water heater to remove sediment and maintain proper operation.

No AC Call: GE R22 unit manufactured in 1983. Found the condenser fan motor not operating. Tested the capacitor and foun...
08/19/2026

No AC Call: GE R22 unit manufactured in 1983. Found the condenser fan motor not operating. Tested the capacitor and found it had failed. Replaced the capacitor, but the condenser fan still did not operate. Tested the fan motor and confirmed the motor had failed.

Replaced the condenser fan capacitor and motor, then verified proper motor rotation and operation. While the unit was disassembled, inspected the condenser coil and found it heavily impacted with dirt and debris. Cleaned the condenser coil and reassembled the unit. System is now operating properly with discharge air temperature approximately 50°F.

🔧 A2L Refrigerant Safety Certified! 🔥At Critical Heating & Hydronics LLC, safety isn’t something we take lightly.We’re p...
08/18/2026

🔧 A2L Refrigerant Safety Certified! 🔥

At Critical Heating & Hydronics LLC, safety isn’t something we take lightly.

We’re proud to be A2L Refrigerant Safety Certified, with training focused on the proper handling, installation, servicing, and safety requirements associated with today’s lower-GWP A2L refrigerants.

As the HVAC industry continues moving toward newer refrigerants such as R-32 and R-454B, proper training is more important than ever. A2L refrigerants are classified as mildly flammable, which means technicians need to understand the proper procedures, equipment, ventilation requirements, leak detection, and safety practices.

Our goal is simple: protect our customers, their families, their employees, and their property while providing professional HVAC service.

When you choose Critical Heating & Hydronics LLC, you can have confidence that we’re staying current with the changing HVAC industry and taking the safety of every installation seriously.

Trained. Certified. Safety First.

📞 Critical Heating & Hydronics LLC
🌐 www.critical-hydronics.com

🔥 32 Years of Service — Time for a New Furnace! 🔥Another furnace replacement completed by Critical Heating & Hydronics!T...
08/17/2026

🔥 32 Years of Service — Time for a New Furnace! 🔥

Another furnace replacement completed by Critical Heating & Hydronics!

This 32-year-old American Standard 80,000 BTU, 80% furnace had provided decades of service, but it was time for retirement. We replaced it with a new Goodman 80,000 BTU, 80% AFUE furnace, maintaining the home’s existing heating capacity while providing a reliable new system for years to come.

But installing a furnace is only half the job — proper commissioning is just as important.

🛠️ Installation & Commissioning Included:
• Removed the 32-year-old furnace
• Installed new Goodman 80,000 BTU 80% furnace
• Adapted and connected the existing ductwork
• Verified gas piping and connections
• Checked and adjusted gas pressure
• Performed an external static pressure test to verify airflow and system resistance
• Performed a combustion analysis to verify proper combustion and safe operation
• Verified flue gas performance and combustion readings
• Tested heating operation and controls
• Completed final system startup and commissioning

The combustion analysis readings were looking very good, and the static pressure and gas pressure checks gave us the information needed to verify the new furnace was operating properly with the existing system.

A furnace replacement isn’t just about putting a new box in place. Proper testing, setup, and commissioning are what make sure that new equipment operates safely, efficiently, and as designed.

After 32 years, this American Standard has officially earned its retirement. 🔥

Need a furnace replaced or want to know how your existing system is performing?

📞 Critical Heating & Hydronics
(585) 310-2258
🌐 critical-hydronics.com

A little HVAC misinformation we came across this week…Not gonna name any HVAC companies, but a customer contacted us aft...
08/09/2026

A little HVAC misinformation we came across this week…

Not gonna name any HVAC companies, but a customer contacted us after being told this was “crystallized carbon monoxide” and that their 80% furnace was being phased out.

Neither is accurate.

Carbon monoxide (CO) is a gas. It doesn’t crystallize or leave behind a powdery residue on a furnace.

What you’re seeing is much more consistent with oxidation/corrosion from the galvanized metal around the flue and draft hood, mixed with accumulated dust. Heat and moisture from years of combustion can cause this type of buildup.

And as far as 80% furnaces go, they’re still a legitimate option for replacement in many existing-home applications. Don’t let someone tell you that you have to replace an existing 80% furnace with a 96% furnace simply because it’s “being phased out.”

HVAC should be diagnosed with facts—not made-up terminology.

— Critical Heating & Hydronics LLC