JB Engineering projects LLC

JB Engineering projects LLC construction and maintenance company, we help with your civil engineering projects, metallic structures, welding, facade painting Total quality is our premise

JB Engineering and Construction LLC is a civil works construction company, which provides construction, consulting and advisory services, auditing, design, remodeling with experience and capacity for the supervision of infrastructure projects and design of sustainable solutions. We provide excellent quality services in infrastructure and committed to the conservation of natural and ecological reso

urces and the environment. JB Engineering and Construction LLC is a company created to provide construction solutions and advance with the development of infrastructure at a national level, for this we have a qualified staff to carry out the projects according to the requirements and needs of the client, complying with all the codes of the state of Indiana, local and State, our works comply in detail with the current technical regulations, quality and safety requirements, but mainly we ensure that the customer ends up fully satisfied with the work delivered.

JB Engineering and Construction LLC is a civil works construction company, which provides construction, consulting and a...
10/13/2024

JB Engineering and Construction LLC is a civil works construction company, which provides construction, consulting and advisory services, auditing, design, remodeling with experience and capacity for the supervision of infrastructure projects and design of sustainable solutions. We provide excellent quality services in infrastructure and committed to the conservation of natural and ecological resources and the environment. JB Engineering and Construction LLC is a company created to provide construction solutions and advance with the development of infrastructure at a national level, for this we have a qualified staff to carry out the projects according to the requirements and needs of the client, complying with all the codes of the state of Indiana, local and State, our works comply in detail with the current technical regulations, quality and safety requirements, but mainly we ensure that the customer ends up fully satisfied with the work delivered. Total quality is our premise

10/13/2024
10/05/2024
08/12/2023

✅traslapes en barras de refuerzo

👉El acero de refuerzo longitudinal en una columna se deja el traslape en la zona central de la columna, evitar los traslapes cerca de las conexiones viga – columna de esta manera se garantiza la ductilidad del elemento estructural y se evita sobre-esforzar la columna en zonas críticas a falla👷‍♂️🇨🇴🚧

It does not comply with the Standard, remember that there are two types of structural designs, 1 that fails due to Tensi...
07/13/2023

It does not comply with the Standard, remember that there are two types of structural designs, 1 that fails due to Tension and 2 that fails by compression. When there is a lot of steel, the failure is due to compression and this is no longer allowed due to several things, firstly, because it is an explosive failure does not give time to see the defects, in the event of an event there is no deflection and there is no time for people to be saved because it is an instantaneous failure, due to tension the steel deflates and the elements generate drifts that visually it makes the structure more elastic and gives time to evacuate, the other one that does not comply is due to the resistance of the Concrete because the average sieve of the aggregates does not reach its homogeneity and consequently it would not produce the required resistance and the following is the famous development length, which is the length with the thickness of the steel necessary for there to be adherence between the steel and the concrete, which obviously cannot be seen in this column, additional construction costs increase unnecessarily.

We design you!Parapet constructionParapets must have the same fire resistance rating as required for supporting walls. O...
04/17/2022

We design you!

Parapet construction

Parapets must have the same fire resistance rating as required for supporting walls. On any side adjacent to the roof surface, the parapet must have noncombustible faces for the upper 18 inches to include backflow and protection materials.

When the roof slopes toward a parapet on slopes greater than 2 vertical units in 12 horizontal units (16.7% slope), the parapet will extend the same height as any part of the roof within a distance of 3 feet, and the height should not be less than 30 inches.




Sabias que en los codigos de la   , los cuartos exteriores o de sol están clasificados en varias categorías para su soli...
04/15/2022

Sabias que en los codigos de la , los cuartos exteriores o de sol están clasificados en varias categorías para su solicitud de permiso con la ciudad y que se debe cumplir lo siguiente:

Manual de construcción de marcos de madera AF & PA.

Norma AISI para el enmarcado de acero conformado en frío Método descriptivo para viviendas de una y dos familias (AISI S230).

Norma de ICC sobre el diseño y construcción de estructuras de troncos (ICC 400).

Cuartos de sol
Las habitaciones solares deben cumplir con las normas AAMA/NPEA/NSA 2100. Con el propósito de aplicar estos criterios en función del uso previsto, el solicitante del permiso o el profesional de diseño deben identificar las habitaciones solares como una de las siguientes categorías.

Categoría I
Una terraza acristalada aislada térmicamente con paredes abiertas o encerradas con mosquiteros o película de plástico de 0,5 de espesor máximo. El espacio es no habitable e incondicionado.

Categoría II
Terraza acristalada aislada térmicamente con paredes cerradas. Las aberturas están cerradas con plástico o vidrio translúcido o transparente. El espacio es no habitable e incondicionado.

Categoría III
terraza acristalada aislada térmicamente con paredes cerradas. Las aberturas están cerradas con plástico o vidrio translúcido o transparente. La fenestración de la habitación solar cumple con los requisitos adicionales de resistencia a la infiltración de aire y resistencia a la penetración de agua. El espacio es no habitable e incondicionado.

Categoría IV
Terraza acristalada aislada térmicamente con paredes cerradas. La cámara solar está diseñada para ser calentada o enfriada por un sistema o control de temperatura separado y está aislada térmicamente de la estructura primaria. La fenestración de la habitación solar cumple con los requisitos adicionales de resistencia a la penetración de agua, resistencia a la infiltración de aire y rendimiento térmico. El espacio es no habitable y acondicionado.

Categoría V
Terraza acristalada con paredes cerradas. La terraza acristalada está diseñada para calentarse o enfriarse y está abierta a la estructura principal. La fenestración de la habitación solar cumple con los requisitos adicionales de resistencia a la penetración de agua, resistencia a la infiltración de aire y rendimiento térmico. El espacio es habitable y acondicionado.

TENGALO PRESENTE A LA SOLICITUD DE SU PERMISO CON LA CIUDAD PARA LA REMODELACION

Condado de Broward
Miami-Dade County Government

Do you know what a sanitary sewer overflow (SSO) is?  keep it in mind when you make your remodeling. Jbengineering Proje...
04/09/2022

Do you know what a sanitary sewer overflow (SSO) is? keep it in mind when you make your remodeling.

Jbengineering Projectsllc


We design your project, we estimate, we build your dreams
03/23/2022

We design your project, we estimate, we build your dreams

Address

3451 S Oaklawn Circle
Bloomington, IN
47401

Alerts

Be the first to know and let us send you an email when JB Engineering projects LLC posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to JB Engineering projects LLC:

Share