Inspect Montana, LLC

  • Home
  • Inspect Montana, LLC
Directions Website Contact the business

Inspect Montana, LLC Montana Property Consultants
Inspection | Testing | Consultation
Residential & Commercial
Est. 2001 Giving your building a checkup is important.

What’s even more important? Choosing the right professional to get the job done right. Inspect Montana LLC is a residential and commercial building inspection company in Lolo, Montana serving Missoula and Ravalli counties, and beyond. Our certified and accredited inspectors have decades of experience in the industry, so you can rest easy knowing your home or commercial building will be inspected right.

Commonly installed during the mid-20th century, these 9”x9” tiles are often associated with asbestos-containing material...
10/10/2026

Commonly installed during the mid-20th century, these 9”x9” tiles are often associated with asbestos-containing materials. Both the tiles themselves and the black adhesive (often called cutback mastic) used beneath them may contain asbestos.

The good news? Asbestos-containing floor tiles generally present a low exposure risk when left intact and undisturbed. The concern arises when they’re broken, sanded, ground, or removed improperly.
#406

30/09/2026

Moisture ants are much smaller than carpenter ants. They exploit wood that is already experiencing decay due to moisture exposure, and are considered a symptom of wood damage rather than the cause.
#406

Inadequate clearances of overhead service conductors above roofs can create safety hazards for contractors and risk dama...
24/09/2026

Inadequate clearances of overhead service conductors above roofs can create safety hazards for contractors and risk damaging both the conductors and the roof surface.
Generally speaking, service conductors ought to have a minimum 8’ clearance above the surface of the roof. However, several exceptions exist within the code allowing reductions in clearance height depending on a number of variables. These exceptions are why we don’t often see service conductors elevated to 8’ above roofs in most residential applications for example.
Regardless of the exceptions at play, there is no instance that would allow the condition shown pictured here, with the conductors resting directly on the roof surface.
#406

More isn’t always better. We found excess CSST gas piping connected and coiled in a crawlspace when only a fraction of t...
17/09/2026

More isn’t always better. We found excess CSST gas piping connected and coiled in a crawlspace when only a fraction of that length was needed to reach the appliance.

Gas piping systems are sized based on factors including pipe diameter, developed length, available gas pressure, and the demand of the connected appliances. Adding unnecessary length increases pressure loss and can reduce the capacity of the piping system.

CSST is a great product when properly sized, supported, bonded, and installed—but the goal is to provide an appropriately sized route to the appliance, not store the extra 50 feet in the crawlspace.
#406

14/09/2026

A storm collar is a weatherproofing component installed around a metal flue or vent where it passes through a roof flashing. 💧

Its primary purpose is to prevent rain, snow, and meltwater from running down the exterior of the vent pipe and entering the building through the gap between the pipe and the roof flashing.
#406

Missing insulation at the wall of a vaulted ceiling with visual and infrared confirmation. 👍     #406
09/09/2026

Missing insulation at the wall of a vaulted ceiling with visual and infrared confirmation. 👍
#406

21/08/2026

DIY mechanical work can create significant hazards when handling gas-burning appliances and exhausts. 😬
#406

19/08/2026

Making the determination between past or ongoing moisture intrusion can be challenging without recent rain or snow, even with all of the modern tools at our disposal such as infrared imaging and moisture detectors. Once water enters a structure it can travel and present in ways and locations that you may not expect.
#406

14/08/2026

Must be an important light 🤷🏻‍♂️
But in all seriousness, extension cords are not designed to be used in permanent applications and electrical devices, such as receptacles, must be secured. Be safe out there!
:
#406

13/08/2026

While not necessarily required at the time of construction for many of the homes we inspect, our modern understanding of where falls in the home are most common leads us to make recommendations to improve the safety of future occupants.
#406

Address


Opening Hours

Monday 08:00 - 18:00
Tuesday 08:00 - 18:00
Wednesday 08:00 - 18:00
Thursday 08:00 - 18:00
Friday 08:00 - 18:00
Saturday 08:00 - 18:00

Alerts

Be the first to know and let us send you an email when Inspect Montana, LLC posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Inspect Montana, LLC:

Shortcuts

  • Want your business to be the top-listed contractor?

Share