June is the month when well systems in Pennsylvania start acting up:
âą Pumps turning on and off rapidly
âą Pressure bouncing up and down
âą Water surging at faucets
âą Pumps running every few seconds
âą Pressure tanks feeling âfullâ or âemptyâ
Homeowners think the pump is dying.
Most of the time, itâs đ»đŒđ đđ”đČ đœđđșđœ â itâs the đœđżđČđđđđżđČ đđźđ»đž and đđđșđșđČđż đđźđđČđż đ±đČđșđźđ»đ±.
đȘđ”đźđ đđ”đŒđżđâđ°đđ°đčđ¶đ»đŽ đźđ°đđđźđčđčđ đ¶đ
Shortâcycling is when the well pump turns on and off too quickly, too often, or under very small water draws.
A healthy system should:
âą Build pressure
âą Rest
âą Deliver water from the pressure tank
âą Then call for the pump again
A shortâcycling system does the opposite â the pump runs constantly because the tank isnât doing its job.
đȘđ”đ đ¶đ đŽđČđđ đđŒđżđđČ đ¶đ» đđđ»đČ
đ) đđ¶đŽđ”đČđż đ”đŒđđđČđ”đŒđčđ± đđźđđČđż đđđČ
âą Gardening
âą Lawn watering
âą Filling pools
âą More showers
âą More laundry
âą Outdoor hoses
đź) đŁđżđČđđđđżđČ đđźđ»đžđ đčđŒđđČ đźđ¶đż đ°đ”đźđżđŽđČ đłđźđđđČđż đ¶đ» đđźđżđș đđČđźđđ”đČđż
âą Heat expands water and air
âą Air charge drifts
âą Bladders flex more
âą Weak bladders fail
âą Tanks waterâlog faster
đŻ) đŁđ„đ©đ đ±đżđ¶đłđ đ¶đ» đđźđżđș đđČđźđđ”đČđż
âą Rubber softens
âą Springs weaken
âą Pressure fluctuates
âą Pump cycles more often
đŠđ¶đŽđ»đ đđŒđđż đđđđđČđș đ¶đ đđ”đŒđżđâđ°đđ°đčđ¶đ»đŽ
âą Pump turns on every few seconds
âą Water pressure rises and falls
âą Faucets surge
âą Shower pressure pulses
âą Pump runs with tiny water draws
âą Pressure tank feels âfullâ or âemptyâ
âą Clicking from the pressure switch
đȘđ”đźđâđ đ°đźđđđ¶đ»đŽ đ¶đ
đ) đȘđźđđČđżâđčđŒđŽđŽđČđ± đœđżđČđđđđżđČ đđźđ»đž
âą Bladder fails
âą Tank fills with water
âą No air cushion
âą Pump cycles constantly
đź) đđ»đ°đŒđżđżđČđ°đ đźđ¶đż đ°đ”đźđżđŽđČ
âą Tank air pressure doesnât match cutâin pressure
âą Even a few PSI off causes cycling
đŻ) đđźđ¶đčđ¶đ»đŽ đœđżđČđđđđżđČ đđđ¶đđ°đ”
âą Contacts wear
âą Rapid clicking
âą Pump turns on/off constantly
đ°) đŁđ„đ© đ±đżđ¶đłđ
âą Warm weather causes sticking and overshooting
âą Pressure swings trigger the pump
đ±) đđČđźđžđ đŒđ» đđ”đČ đđČđčđč đđ¶đ±đČ
âą Pinholes
âą Cracked fittings
âą Bad check valves
âą Leaking pitless adapters
đȘđ”đ đđ”đŒđżđâđ°đđ°đčđ¶đ»đŽ đžđ¶đčđčđ đœđđșđœđ
âą Motors overheat
âą Contacts burn
âą Windings fail
âą Pump life drops from 10â15 years to 2â3
đđŒđ đđŒ đłđ¶đ
đ¶đ
đ) đđ”đČđ°đž đđ”đČ đœđżđČđđđđżđČ đđźđ»đž đźđ¶đż đ°đ”đźđżđŽđČ
âą Tank must be empty
âą Charge to 2 PSI below cutâin
đź) đ§đČđđ đđ”đČ đŻđčđźđ±đ±đČđż
âą If ruptured, tank waterâlogs
âą Waterâlogged tanks must be replaced
đŻ) đđ»đđœđČđ°đ đđ”đČ đœđżđČđđđđżđČ đđđ¶đđ°đ”
âą Look for burnt contacts
âą Listen for rapid clicking
đ°) đđ”đČđ°đž đłđŒđż đčđČđźđžđ đŒđ» đđ”đČ đđČđčđč đđ¶đ±đČ
âą Even tiny leaks trigger cycling
đ±) đđđźđčđđźđđČ đđ”đČ đŁđ„đ©
âą Warm weather causes drift
âą Drift = unstable pressure
đČ) đđŒđ»đđ¶đ±đČđż đđœđđ¶đđ¶đ»đŽ đđ”đČ đđźđ»đž
âą Bigger tank = fewer cycles = longer pump life
đđŒđ đđŒ đđČđčđč đ¶đł đ¶đâđ đđČđźđđŒđ»đźđč đŒđż đłđźđ¶đčđđżđČ
đŠđČđźđđŒđ»đźđč:
âą Only shortâcycles during heavy use
âą Pressure swings on hot days
âą System stabilizes at night
âą Air charge slightly low
đđźđ¶đčđđżđČ:
âą Tank waterâlogged
âą Bladder ruptured
âą Switch clicking nonstop
âą Pump runs every few seconds
âą Pressure never stabilizes
đđŒđđđŒđș đčđ¶đ»đČ
đȘđČđčđč đœđđșđœ đđ”đŒđżđâđ°đđ°đčđ¶đ»đŽ đ¶đđ»âđ đź đœđđșđœ đœđżđŒđŻđčđČđș â đ¶đâđ đź đœđżđČđđđđżđČ đđźđ»đž đźđ»đ± đđđșđșđČđż đđźđđČđż đ±đČđșđźđ»đ± đœđżđŒđŻđčđČđș.
đđ¶đ
đđ”đČ đđźđ»đž, đłđ¶đ
đđ”đČ đœđżđČđđđđżđČ, đźđ»đ± đđ”đČ đœđđșđœ đđđŒđœđ đ°đđ°đčđ¶đ»đŽ đ¶đđđČđčđł đđŒ đ±đČđźđđ”.
If youâre seeing this in your own home, drop it into the Workshop and weâll walk through whatâs going on.