07/31/2026
Ever wonder why we talk so much about air flow and how it can make or break your systems performance This why we continuously educate our team on the value we can bring for our community with uncompromised results. This was one of our new installs including ducting. (12,0000 btus is 1 ton of cooling) First one was default settings operating at 22,000 btus with a 2 ton ac. No changes just thrown together and turned on. We made a fan speed adjustment because the load calculations called for 23,000 btuhs at 1050 cfm with 70 degrees indoors 50% relative humidity at 95 Degrees outside. (Which is also what equipment rated output is tested at). After adding a couple of ounces to hit our target charge and going up one fan speed to get all little closer to design air flow we got our final output testing. What are the results you ask?
30,000 btuhs thats 2.5 tons of effective cooling.
WAIT A MINUTE! YOU CAN GET MORE COOLING THAN WHAT IT'S RATED FOR?
This is what makes Cripe Heating and air different.
While we cost more than others we dont comprise the results anyone else could offer but don't slow down to provide the best results possible.
So remember if your not comfortable Don't Gripe Call Cripe!!