08/03/2026
This 14-year-old HVAC system had leaking underground copper refrigerant lines and a leaking evaporator coil. Instead of simply topping off the refrigerant as had been done previously, we performed a thorough leak search and identified the source of the problem. With multiple refrigerant leaks and the age of the equipment, continued repairs would have become increasingly costly, making a full system replacement the most reliable and cost-effective long-term solution.
We installed a new high-efficiency system, replaced the refrigerant line set, performed a nitrogen test, pull a deep vacuum under 500 microns, charged the system to manufacturer specifications, and verified proper airflow and operating performance before completion.
We believe a quality installation is just as important as the equipment itself. Proper installation helps maximize efficiency, improve reliability, and extend the life of the system.
Thank you to our valued customer for trusting Ascend Heating & Air Conditioning with your home comfort!