When an HVAC proposal says “3.5 ton,” should the certified capacity always be exactly 42,000 BTUH?
Not necessarily.
For this McKinney, TX 75070 project, the homeowner reported that the home was not cooling. The approved replacement included:
✅ nominal 3.5-ton Daikin R-32 straight-cool A/C
✅ matched horizontal evaporator coil
✅ 80,000-BTU-input, 80% AFUE gas furnace
✅ AHRI 214856170: 39,000 BTUH, 15.2 SEER2 and 12.0 EER2
✅ written installation scope and labor-warranty terms
“Nominal 3.5 ton” describes the equipment class. The exact certified performance belongs to the complete condenser, coil and furnace/blower combination.
The homeowner received the equipment information, AHRI reference, included work and warranty terms before approving the replacement. That documentation gives homeowners a clearer basis for comparing proposals than brand or tonnage alone.
Read the full McKinney case study: