BluePrime Aircon and Refrigeration Services

BluePrime Aircon and Refrigeration Services Professional aircon, HVAC, and refrigeration services in Iloilo for homes and businesses.

Completed work for a Midea 1.0HP window-type inverter aircon with weak cooling concern in Jaro, Iloilo City.For window-t...
04/10/2026

Completed work for a Midea 1.0HP window-type inverter aircon with weak cooling concern in Jaro, Iloilo City.

For window-type aircon cleaning and maintenance inquiries, message BluePrime anytime.
πŸ’¬ m.me/blueprimeaircon



Before and after: Midea U-shaped aircon deep cleaningNeed your aircon cleaned or checked? Message us to schedule ahead.πŸ’¬...
03/10/2026

Before and after: Midea U-shaped aircon deep cleaning

Need your aircon cleaned or checked? Message us to schedule ahead.
πŸ’¬ m.me/blueprimeaircon



Kumusta na ang outdoor unit mo?Dali, kay istoryahan ta.For split-type aircons, the outdoor unit also needs attention.It ...
02/10/2026

Kumusta na ang outdoor unit mo?
Dali, kay istoryahan ta.

For split-type aircons, the outdoor unit also needs attention.

It sits outside where it can collect:
βœ… dust and dirt
βœ… leaves and debris
βœ… insects or small pests
βœ… moisture and weather exposure

If infestation or heavy dirt reaches the wiring, sensor areas, or PCB components, it may affect normal operation and can lead to errors, shutdowns, or cooling problems.

A few simple household reminders:
πŸ”§ Keep the area around the outdoor unit clear
πŸ”§ Avoid piling boxes, plants, or other items around it
πŸ”§ Watch for insects, nests, unusual noise, or repeated error codes
πŸ”§ Have the unit checked if something looks unusual

The indoor unit is only half of the system.

Don’t forget the outdoor unit too.

For aircon cleaning, troubleshooting, and maintenance inquiries, message BluePrime anytime.
πŸ’¬ m.me/blueprimeaircon






01/10/2026

Completed repair work for a Midea 1.5HP split-type inverter aircon with water leakage from the indoor unit.

Upon checking, the unit had:
βœ… Clogged secondary drain pan
βœ… Indoor pipeline insulation that needed replacement / reinsulation
βœ… Dirt buildup requiring pull-down cleaning
βœ… System condition requiring reprocess

Completed work included:
πŸ”§ Pull-down of evaporator coil
πŸ”§ General cleaning of indoor unit and evaporator coil
πŸ”§ Cleaning and clearing of secondary drain pan
πŸ”§ Reinsulation of indoor pipeline
πŸ”§ System reprocess
πŸ”§ Testing after service

Water leakage is not always just a simple drain issue.

Dirt buildup, clogged drainage, damaged insulation, or other system concerns can all contribute.

That’s why proper checking matters before fixing the leak.

For aircon water leakage, deep cleaning, system reprocess, and repair inquiries, message BluePrime anytime.








Sometimes, regular cleaning is not enough.Dali, kay istoryahan ta.For split-type aircons, dirt and blockage can build up...
30/09/2026

Sometimes, regular cleaning is not enough.
Dali, kay istoryahan ta.

For split-type aircons, dirt and blockage can build up in areas that are difficult to reach during normal cleaning, especially around the evaporator coil, blower area, drain pan, and drainage path.

That’s when pull-down or deep cleaning may be recommended.

By pulling down key parts of the indoor unit, technicians can get better access to:
βœ… deeper dirt buildup behind the evaporator coil
βœ… clogged or dirty drain pans
βœ… hard-to-reach areas affecting airflow
βœ… moisture and buildup that may contribute to odor or water leakage
βœ… areas that cannot be properly cleaned while the unit is still fully assembled

This does not mean every aircon needs pull-down cleaning.

It is usually recommended based on the actual condition of the unit, especially when regular cleaning cannot fully address the problem.

Regular cleaning maintains the unit. Deep cleaning addresses buildup that regular cleaning may not reach.

At BluePrime, we check first before recommending deeper service.

For split-type aircon cleaning, pull-down cleaning, water leakage, and maintenance inquiries, message BluePrime anytime.
πŸ’¬ m.me/blueprimeaircon







Repair highlight: 2.0HP Carrier split-type aircon with a defective outdoor PCB board.πŸ”§For inverter split-type aircons, t...
29/09/2026

Repair highlight: 2.0HP Carrier split-type aircon with a defective outdoor PCB board.πŸ”§

For inverter split-type aircons, the outdoor PCB helps control important functions of the outdoor unit.

When the board develops a fault, the aircon may stop cooling properly, shut down, show errors, or fail to operate as expected.

For this Carrier 2.0HP unit, the concern was traced to the outdoor PCB.

Proper checking matters because a PCB issue should be confirmed before recommending repair or replacement.

For aircon PCB concerns, troubleshooting, and repair inquiries, message BluePrime anytime.







28/09/2026

Repiping works for this Boston Bay 2.5HP split-type aircon in Arevalo, Iloilo City.

For split-type aircon repiping, leak concerns, and system reprocess, message BluePrime anytime.






27/09/2026

Keep showing upπŸ˜ŽπŸ”§

Repair in progress for a Panasonic 1.5HP window-type inverter aircon with H97 error.For Panasonic aircons, H97 is associ...
26/09/2026

Repair in progress for a Panasonic 1.5HP window-type inverter aircon with H97 error.

For Panasonic aircons, H97 is associated with an outdoor fan motor mechanism lock or abnormal fan feedback.

Possible causes can involve the fan motor, its wiring or connector, or the control board, depending on the actual unit condition.

That’s why the error code is only the starting point.

The unit still needs proper checking to determine what is actually preventing the fan system from operating normally before recommending repair.

πŸ”§ Error code confirmed
πŸ”§ Fan operation checked
πŸ”§ Wiring and connections inspected
πŸ”§ Actual cause being diagnosed

Repair currently in progress.

Error code gives the clue. Proper checking finds the cause.

For inverter aircon error codes, troubleshooting, and repair inquiries, message BluePrime anytime. πŸ’¬ m.me/blueprimeaircon






25/09/2026

Repiping work on Boston Bay 2.5HP wall-mounted split-type aircon
πŸ”§ Repiping of refrigerant line
πŸ”§ Leak checking using nitrogen pressure
πŸ”§ Inspection of flare joints, service valves, and exposed copper line
πŸ”§ Repair or reflare of leaking section as needed
πŸ”§ Proper reinsulation of copper pipeline
πŸ”§ System reprocess

Address

Iloilo
Iloilo City
5000

Website

Alerts

Be the first to know and let us send you an email when BluePrime Aircon and Refrigeration Services posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Shortcuts

Share