D&C Structure Design

Directions

D&C Structure Design D&C Structure Design are team of freelance for Design Structure & Architectural, Typical Drawing, Shop drawing and BOQ
Telegram; t.me/DCStructure168

24/08/2026
πŸ—οΈ Hyperstatic Moment αž€αŸ’αž“αž»αž„ PT Slab αž˜αžΆαž“αž“αŸαž™αžŠαžΌαž…αž˜αŸ’αžαŸαž…? αž αŸαžαž»αž’αŸ’αžœαžΈ Structural Engineer αžαŸ’αžšαžΌαžœαžŸαž·αž€αŸ’αžŸαžΆ?αžαžΎαž’αŸ’αž“αž€αž’αŸ’αž›αžΆαž”αŸ‹αž†αŸ’αž„αž›αŸ‹αž‘αŸαžαžΆαŸ–αž αŸαžαž»αž’...
24/08/2026

πŸ—οΈ Hyperstatic Moment αž€αŸ’αž“αž»αž„ PT Slab αž˜αžΆαž“αž“αŸαž™αžŠαžΌαž…αž˜αŸ’αžαŸαž…? αž αŸαžαž»αž’αŸ’αžœαžΈ Structural Engineer αžαŸ’αžšαžΌαžœαžŸαž·αž€αŸ’αžŸαžΆ?
αžαžΎαž’αŸ’αž“αž€αž’αŸ’αž›αžΆαž”αŸ‹αž†αŸ’αž„αž›αŸ‹αž‘αŸαžαžΆαŸ–
αž αŸαžαž»αž’αŸ’αžœαžΈ PT Slab αžαŸ’αžšαžΌαžœαž˜αžΆαž“ β€œHyperstatic Moment”? αž αžΎαž™αžœαžΆαž€αžΎαžαž˜αž€αž–αžΈαžŽαžΆ?

αžαŸ’αž„αŸƒαž“αŸαŸ‡ D&C Structure Design αžŸαžΌαž˜αž–αž“αŸ’αž™αž›αŸ‹αž‡αžΆαž—αžΆαžŸαžΆαž„αžΆαž™αŸ— αžŠαŸ„αž™αž”αŸ’αžšαžΎαž§αž‘αžΆαž αžšαžŽαŸαž‡αžΆαž€αŸ‹αžŸαŸ’αžαŸ‚αž„αŸ” πŸ‘‡

πŸ”Ή 1. αž…αžΆαž”αŸ‹αž•αŸ’αžαžΎαž˜αž–αžΈ PT Tendon

αžŸαŸ’αžšαž˜αŸƒαžαžΆ αž™αžΎαž„αž˜αžΆαž“ PT Slab αž˜αž½αž™ αžŠαŸ‚αž›αž˜αžΆαž“ Tendon αžŠαžΆαž€αŸ‹αž‡αžΆαž‘αž˜αŸ’αžšαž„αŸ‹αŸ–

High β†’ Low β†’ High

αž“αŸ…αž–αŸαž›αž™αžΎαž„ Stress/Tension Tendon αžœαžΆαž“αžΉαž„αž”αž‰αŸ’αž…αŸαž‰αž€αž˜αŸ’αž›αžΆαŸ†αž„ Prestressing Force αž‘αŸ…αž›αžΎ SlabαŸ”

αž“αž·αž™αžΆαž™αž²αŸ’αž™αžŸαžΆαž˜αž‰αŸ’αž‰αŸ–

Tendon αžαŸ’αžšαžΌαžœαž”αžΆαž“αž‘αžΆαž‰ β†’ Tendon αž…αž„αŸ‹αž”αž„αŸ’αž€αžΎαžαž€αžΆαžšαž•αŸ’αž›αžΆαžŸαŸ‹αž‘αžΈ/Deformation β†’ Slab αž‘αž‘αž½αž›αž€αž˜αŸ’αž›αžΆαŸ†αž„

πŸ”Ή 2. αžαŸ‚ Slab αž˜αž·αž“αž’αžΆαž…αž•αŸ’αž›αžΆαžŸαŸ‹αž‘αžΈαžŠαŸ„αž™αžŸαŸαžšαžΈαž‘αŸ!

αžŸαŸ’αžšαž˜αŸƒαžαžΆ Slab αžšαž”αžŸαŸ‹αž™αžΎαž„αž˜αžΆαž“ Column αž“αŸ…αžαžΆαž„αž€αŸ’αžšαŸ„αž˜αŸ–

Slab β†’ Column β†’ Foundation

αž“αŸ…αž–αŸαž› Tendon αž–αŸ’αž™αžΆαž™αžΆαž˜αž’αŸ’αžœαžΎαž²αŸ’αž™ Slab αž•αŸ’αž›αžΆαžŸαŸ‹αž‘αžΈ ឬ Deform តអម Tendon Profile αž”αŸ‰αž»αž“αŸ’αžαŸ‚ Column αž“αž·αž„ Wall αžšαžΆαžšαžΆαŸ†αž„αžœαžΆαŸ”

αžŠαžΌαž…αŸ’αž“αŸαŸ‡ Structure αž“αž·αž™αžΆαž™αžαžΆαŸ–

β€œαžαŸ’αž‰αž»αŸ†αž˜αž·αž“αž’αž“αž»αž‰αŸ’αž‰αžΆαžαž²αŸ’αž™αž’αŸ’αž“αž€αž•αŸ’αž›αžΆαžŸαŸ‹αž‘αžΈαžŠαŸ„αž™αžŸαŸαžšαžΈαž‘αŸ!” πŸ˜„

αž€αžΆαžšαžšαžΆαžšαžΆαŸ†αž„αž“αŸαŸ‡αž”αž„αŸ’αž€αžΎαžαž‡αžΆ Secondary Reaction αž αžΎαž™αž”αž“αŸ’αžαž”αž„αŸ’αž€αžΎαžαž‡αžΆ Secondary MomentαŸ”

Moment αž“αŸαŸ‡αž αžΎαž™αžŠαŸ‚αž›αž™αžΎαž„αž αŸ…αžαžΆαŸ–

πŸ‘‰ Hyperstatic Moment
πŸ”Ή 3. αž§αž‘αžΆαž αžšαžŽαŸαž„αžΆαž™αŸ—αžŠαžΌαž…αž‡αžΆ β€œαžαŸ’αžŸαŸ‚αž–αž½αžšβ€

αžŸαŸ’αžšαž˜αŸƒαžαžΆ αž’αŸ’αž“αž€αž˜αžΆαž“αžαŸ’αžŸαŸ‚αž–αž½αžšαž˜αž½αž™αž…αž„αž“αŸ…αž‡αž‰αŸ’αž‡αžΆαŸ†αž„αž–αžΈαžšαžαžΆαž„αŸ”

Wall 🧱 ───── Rope ───── 🧱 Wall

αž’αŸ’αž“αž€αž‘αžΆαž‰αžαŸ’αžŸαŸ‚αž–αž½αžšαž±αŸ’αž™αžαžΉαž„αŸ”

αžαŸ’αžŸαŸ‚αž–αž½αžšαž…αž„αŸ‹αž•αŸ’αž›αžΆαžŸαŸ‹αž‘αžΈ αž”αŸ‰αž»αž“αŸ’αžαŸ‚αž‡αž‰αŸ’αž‡αžΆαŸ†αž„αž‘αžΆαŸ†αž„αž–αžΈαžšαžšαžΆαžšαžΆαŸ†αž„αžœαžΆαŸ”

αžŠαžΌαž…αŸ’αž“αŸαŸ‡αž€αž˜αŸ’αž›αžΆαŸ†αž„αž–αžΈαž€αžΆαžšαž‘αžΆαž‰ αž˜αž·αž“αž”αžΆαžαŸ‹αž‘αŸ…αžŽαžΆαž‘αŸ αž”αŸ‰αž»αž“αŸ’αžαŸ‚αžαŸ’αžšαžΌαžœαž”αžΆαž“αž”αž‰αŸ’αž‡αžΌαž“αž‘αŸ…αž‡αž‰αŸ’αž‡αžΆαŸ†αž„αŸ”

PT Tendon αž€αŸαž˜αžΆαž“αž‚αŸ†αž“αž·αžαžŸαŸ’αžšαžŠαŸ€αž„αž‚αŸ’αž“αžΆαŸ–

PT Force β†’ Slab β†’ Column/Wall Restraint β†’ Secondary Reaction

αž αžΎαž™ Secondary Reaction αž“αŸαŸ‡αž’αžΆαž…αž”αž„αŸ’αž€αžΎαž Hyperstatic MomentαŸ”

πŸ”Ή 4. αž§αž‘αžΆαž αžšαžŽαŸαž‡αžΆαž˜αž½αž™ PT Slab

αžŸαŸ’αžšαž˜αŸƒαžαžΆ PT Slab αž˜αžΆαž“ Column 3 αž‡αž½αžšαŸ–

Column ┃────────┃────────┃ Column

PT Tendon αžαŸ’αžšαžΌαžœαž”αžΆαž“ TensionαŸ”

αž”αžΎ Slab αž’αžΆαž…αž•αŸ’αž›αžΆαžŸαŸ‹αž‘αžΈαžŠαŸ„αž™αžŸαŸαžšαžΈ β†’ Secondary Effect αžαž·αž…αŸ”

αž”αŸ‰αž»αž“αŸ’αžαŸ‚αžŠαŸ„αž™αžŸαžΆαžš Column αž“αž·αž„ Wall αžšαžΆαžšαžΆαŸ†αž„ Slab β†’ Secondary Effect αž€αžΎαžαž‘αžΎαž„αŸ”

αžŠαžΌαž…αŸ’αž“αŸαŸ‡αŸ–

PT Tendon
⬇️
Prestress Force
⬇️
Slab αž…αž„αŸ‹ Deform
⬇️
Column/Wall αžšαžΆαžšαžΆαŸ†αž„
⬇️
Secondary Reaction
⬇️

Hyperstatic Moment
πŸ”Ή 5. αžαžΎαžœαžΆαž’αžΆαž…αž”αŸ‰αŸ‡αž–αžΆαž›αŸ‹αžŠαž›αŸ‹ Moment αž™αŸ‰αžΆαž„αžŠαžΌαž…αž˜αŸ’αžαŸαž…?

αžŸαŸ’αžšαž˜αŸƒαžαžΆ Gravity Load αž”αž„αŸ’αž€αžΎαž Moment αž˜αž½αž™αŸ–

Gravity Moment = 500 kNm

αž”αž“αŸ’αž‘αžΆαž”αŸ‹αž–αžΈαž™αžΎαž„αž–αž·αž…αžΆαžšαžŽαžΆ Hyperstatic Effect αžƒαžΎαž‰αžαžΆαŸ–

Hyperstatic Moment = -120 kNm

αž€αŸ’αž“αž»αž„αž€αžšαžŽαžΈαž“αŸαŸ‡ PT Secondary Effect αž’αžΆαž…αž‡αž½αž™ αž€αžΆαžαŸ‹αž”αž“αŸ’αžαž™ Moment αž“αŸ…αžαŸ†αž”αž“αŸ‹αž“αŸ„αŸ‡αŸ”

ConceptuallyαŸ–

500 βˆ’ 120 = 380 kNm

αž”αŸ‰αž»αž“αŸ’αžαŸ‚ ⚠️ αžαŸ’αžšαžΌαžœαž…αžΆαŸ†αžαžΆ Hyperstatic Moment αž˜αž·αž“αžαŸ‚αž„αžαŸ‚αž€αžΆαžαŸ‹αž”αž“αŸ’αžαž™ Gravity Moment αž‘αŸαŸ” αž“αŸ…αžαŸ†αž”αž“αŸ‹αž•αŸ’αžŸαŸαž„ αžœαžΆαž’αžΆαž…αž˜αžΆαž“αž‘αž·αžŸαžŠαžΌαž…αž‚αŸ’αž“αžΆ αž αžΎαž™αž’αŸ’αžœαžΎαž±αŸ’αž™ Moment αž€αžΎαž“αž‘αžΎαž„αŸ”

αžŠαžΌαž…αŸ’αž“αŸαŸ‡ Engineer αžαŸ’αžšαžΌαžœαž–αž·αž“αž·αžαŸ’αž™ Sign αž“αž·αž„ Load Combination αž±αŸ’αž™αž”αžΆαž“αžαŸ’αžšαžΉαž˜αžαŸ’αžšαžΌαžœαŸ”

πŸ”Ή 6. αž αŸαžαž»αž’αŸ’αžœαžΈ Structural Engineer αžαŸ’αžšαžΌαžœαžŸαž·αž€αŸ’αžŸαžΆαžœαžΆ?

αž–αŸ’αžšαŸ„αŸ‡ Hyperstatic Moment αž’αžΆαž…αž˜αžΆαž“αž₯αž‘αŸ’αž’αž·αž–αž›αž›αžΎαŸ–

πŸ—οΈ PT Slab Moment
πŸ”© Reinforcement
🏒 Column
🧱 Wall
⬇️ Support Reaction
🏠 Foundation

αž”αŸ’αžšαžŸαž·αž“αž”αžΎαž™αžΎαž„αž˜αžΎαž›αžαŸ‚ Gravity Load αž αžΎαž™αž˜αž·αž“αž™αž›αŸ‹αž–αžΈ PT Secondary Effect αž™αžΎαž„αž’αžΆαž…αž˜αžΎαž›αžšαŸ†αž›αž„αž₯αž‘αŸ’αž’αž·αž–αž›αž˜αž½αž™αžŠαŸ‚αž›αžŸαŸ†αžαžΆαž“αŸ‹αž€αŸ’αž“αž»αž„ PT StructureαŸ”

πŸ“Œ αž…αŸ†αžŽαž»αž…αžŸαž˜αŸ’αžšαžΆαž”αŸ‹αž’αŸ’αž“αž€αž…αžΆαž”αŸ‹αž•αŸ’αžαžΎαž˜αžšαŸ€αž“

αž€αž»αŸ†αž…αžΆαŸ†αžαŸ‚αž–αžΆαž€αŸ’αž™ Hyperstatic MomentαŸ” αžŸαžΌαž˜αž…αžΆαŸ†αž‡αžΆαžαŸ’αžŸαŸ‚αžŸαž„αŸ’αžœαžΆαž€αŸ‹αž“αŸαŸ‡αŸ–

Tendon αžαŸ’αžšαžΌαžœαž”αžΆαž“ Tension β†’ Slab αž…αž„αŸ‹ Deform β†’ Structure αžšαžΆαžšαžΆαŸ†αž„ β†’ αž€αžΎαž Reaction β†’ αž€αžΎαž Secondary Moment β†’ Hyperstatic Moment

αž“αž·αž™αžΆαž™αžαŸ’αž›αžΈαž”αŸ†αž•αž»αžαŸ–

Hyperstatic Moment = Moment αžŠαŸ‚αž›αž€αžΎαžαž–αžΈαž€αžΆαžšαžšαžΆαžšαžΆαŸ†αž„αžšαž”αžŸαŸ‹ Structure αž…αŸ†αž–αŸ„αŸ‡ Prestressing EffectαŸ”

πŸ’‘ αžŠαžΌαž…αŸ’αž“αŸαŸ‡ αž“αŸ…αž–αŸαž›αž’αŸ’αž“αž€αžƒαžΎαž‰αž€αŸ’αž“αž»αž„ ETABSαŸ–

PT-FINAL-HP β†’ Hyperstatic

αžŸαžΌαž˜αž“αžΉαž€αžƒαžΎαž‰αž—αŸ’αž›αžΆαž˜αŸ—αžαžΆαŸ–

β€œαž“αŸαŸ‡αž‚αžΊαž€αžΆαžšαžŸαž·αž€αŸ’αžŸαžΆαž–αžΈ Secondary Effect αžŠαŸ‚αž›αž€αžΎαžαž‘αžΎαž„αžŠαŸ„αž™αžŸαžΆαžš PT Tendon αžαŸ’αžšαžΌαžœαž”αžΆαž“αžšαžΆαžšαžΆαŸ†αž„αžŠαŸ„αž™ Structural Systemΰ₯€β€

πŸ—οΈ D&C Structure Design
Sharing Structural Engineering Knowledge for Better & Safer Design.
Joint Channel: t.me/dcstructuresharingknowledge

1. Diaphragm αž‚αžΊαž‡αžΆαž’αŸ’αžœαžΈ?Diaphragm αž‚αžΊαž‡αžΆ floor/roof system αžŠαŸ‚αž›αž‡αž½αž™αž”αŸ’αžšαž˜αžΌαž› αž“αž·αž„αž”αž‰αŸ’αž‡αžΌαž“ horizontal load αž‘αŸ…αž€αžΆαž“αŸ‹ lateral-resisting e...
11/08/2026

1. Diaphragm αž‚αžΊαž‡αžΆαž’αŸ’αžœαžΈ?

Diaphragm αž‚αžΊαž‡αžΆ floor/roof system αžŠαŸ‚αž›αž‡αž½αž™αž”αŸ’αžšαž˜αžΌαž› αž“αž·αž„αž”αž‰αŸ’αž‡αžΌαž“ horizontal load αž‘αŸ…αž€αžΆαž“αŸ‹ lateral-resisting elements αžŠαžΌαž…αž‡αžΆαŸ–

- Shear Wall
- Moment Frame
- Braced Frame
αž§αž‘αžΆαž αžšαžŽαŸαŸ–
Earthquake β†’ Floor Slab β†’ Shear Wall/Column Frame β†’Foundation
2. Rigid Diaphragm

Rigid = αž…αžΆαžαŸ‹αž‘αž»αž€αžαžΆ Floor Slab αžšαžΉαž„αžαŸ’αž›αžΆαŸ†αž„αž€αŸ’αž“αž»αž„ plane αžšαž”αžŸαŸ‹αžœαžΆαŸ”

αž€αŸ’αž“αž»αž„ ETABS αž”αŸ’αžšαžŸαž·αž“αž”αžΎαž™αžΎαž„αž‡αŸ’αžšαžΎαžŸ Rigid αžœαžΆαžŸαž“αŸ’αž˜αžαŸ‹αžαžΆ slab αž˜αž·αž“ deform αž“αŸ…αž€αŸ’αž“αž»αž„ plane (XY) ឬ deform αžαž·αž…αž”αŸ†αž•αž»αžαŸ”

αž˜αžΆαž“αž“αŸαž™αžαžΆ αž…αŸ†αžŽαž»αž…αž‘αžΆαŸ†αž„αž’αžŸαŸ‹αž“αŸ…αž›αžΎ floor αž˜αž½αž™αŸ–

- αž˜αžΆαž“ lateral translation αž‘αžΆαž€αŸ‹αž‘αž„αž‚αŸ’αž“αžΆ
- αž’αžΆαž…αž˜αžΆαž“ rotation αžšαž½αž˜αž‚αŸ’αž“αžΆ
- Floor αž’αŸ’αžœαžΎαžŠαžΌαž…αž‡αžΆ rigid plate
αž§αž‘αžΆαž αžšαžŽαŸαž„αžΆαž™αŸ—
αžŸαŸ’αžšαž˜αŸƒαžαžΆ floor αžšαž”αžŸαŸ‹αž’αŸ’αž“αž€αž‡αžΆ αžŠαŸ‚αž€αž˜αž½αž™αžŠαž»αŸ†αžšαžΉαž„αŸ–

Earthquake β†’
β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ β”‚
β”‚ FLOOR β”‚
β”‚ β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜
↻ Rotation
αž–αŸαž› lateral force αž˜αž€ Floor αž“αžΉαž„αž•αŸ’αž‘αŸαžš force αž‘αŸ… columns/shear walls តអម stiffness αž“αž·αž„αž‘αžΈαžαžΆαŸ†αž„αžšαž”αžŸαŸ‹αžœαžΆαŸ”

αž’αžαŸ’αžαž”αŸ’αžšαž™αŸ„αž‡αž“αŸ
Rigid diaphragmαŸ–
- Model αž„αžΆαž™
- Analysis αž›αžΏαž“
- αž˜αžΆαž“ fewer DOF
- αžŸαž˜αžŸαŸ’αžšαž”αžŸαž˜αŸ’αžšαžΆαž”αŸ‹ floor αžŠαŸ‚αž›αž˜αžΆαž“ stiffness αž€αŸ’αž“αž»αž„ plane αžαŸ’αž–αžŸαŸ‹
- αž‡αžΆαž‘αžΌαž‘αŸ…αž”αŸ’αžšαžΎαž”αžΆαž“αž›αŸ’αž’αžŸαž˜αŸ’αžšαžΆαž”αŸ‹ RC slab αžŠαŸ‚αž›αž˜αžΆαž“ continuity αž›αŸ’αž’

3. Semi-Rigid Diaphragm
Semi-Rigid = αž±αŸ’αž™ ETABS αž‚αž·αžαž–αžΈ stiffness αž–αž·αžαžšαž”αžŸαŸ‹ slabαŸ” αž“αŸαŸ‡αž˜αžΆαž“αž“αŸαž™αžαžΆ slab αž’αžΆαž… deform αž“αŸ…αž€αŸ’αž“αž»αž„ planeαŸ”

αž§αž‘αžΆαž αžšαžŽαŸαŸ–
Earthquake β†’

β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ β†’ β”‚
β”‚ β†˜ β”‚
β”‚ β†˜ β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜
Deformation

ETABS αž“αžΉαž„αž‚αž·αžαž–αžΈαŸ–
- Slab thickness
- Concrete stiffness
- Cracking assumptions
- Geometry
- Openings
- Mesh
- Slab membrane stiffness
αžŠαžΌαž…αŸ’αž“αŸαŸ‡ force distribution αž‘αŸ… columns αž“αž·αž„ shear walls αž’αžΆαž…αžαž»αžŸαž–αžΈ Rigid diaphragmαŸ”

4. αž—αžΆαž–αžαž»αžŸαž‚αŸ’αž“αžΆαžŸαŸ†αžαžΆαž“αŸ‹
1. Slab in-plane deformation
- Rigid (αž˜αž·αž“αž‚αž·αž/αžαž·αž…αž”αŸ†αž•αž»αž)
- Semi-Rigid (αž‚αž·αž).
2. Slab stiffness
- Rigid (αž˜αž·αž“αž”αŸ’αžšαžΎαžŠαžΎαž˜αŸ’αž”αžΈ distribute in-plane deformation)
- Semi-Rigid (αž”αŸ’αžšαžΎ stiffness αžšαž”αžŸαŸ‹ slab)
3. Model
- Rigid (αž„αžΆαž™ Model)
- Semi-Rigid (Model αž›αž˜αŸ’αž’αž·αžαž‡αžΆαž„)
4. Analysis
- Rigid (αž›αžΏαž“)
- Semi-Rigid (αž™αžΊαžαž‡αžΆαž„)
5. Mesh slab
- Rigid (αž˜αž·αž“αžŸαŸ†αžαžΆαž“αŸ‹αžŸαž˜αŸ’αžšαžΆαž”αŸ‹ diaphragm behavior)
- Semi-Rigid (αžŸαŸ†αžαžΆαž“αŸ‹)
6. Force distribution
- Rigid (Based mainly on rigid-body behavior)
- Semi-Rigid (Based on slab + frame stiffness)
7. Large openings
- Rigid (αž˜αž·αž“αžŸαžΌαžœ represent αž”αžΆαž“αž›αŸ’αž’)
- Semi-Rigid (Better)
8. Flexible diaphragm
- Rigid (αž˜αž·αž“αžŸαž˜αžŸαŸ’αžšαž”)
- Semi-Rigid (αžŸαž˜αžŸαŸ’αžšαž”)

5. αž…αŸ†αžŽαž»αž…αžŸαŸ†αžαžΆαž“αŸ‹αž”αŸ†αž•αž»αžαžŸαž˜αŸ’αžšαžΆαž”αŸ‹ Structural Engineer
αž€αž»αŸ†αž‚αž·αžαžαžΆαŸ–
Rigid = Slab αž˜αžΆαž“ concrete strength αžαŸ’αž–αžŸαŸ‹
αž“αŸ„αŸ‡αž˜αž·αž“αž˜αŸ‚αž“αž‡αžΆαž’αžαŸ’αžαž“αŸαž™αž‘αŸαŸ”
Rigid diaphragm αž‚αžΊαž“αž·αž™αžΆαž™αž’αŸ†αž–αžΈ in-plane stiffness/deformation αžšαž”αžŸαŸ‹ floor diaphragmαŸ”

αž§αž‘αžΆαž αžšαžŽαŸ slab RC αž˜αž½αž™αž’αžΆαž…αž˜αžΆαž“:
- 150 mm thickness
- Concrete f'c = 25 MPa
- Reinforcement αž˜αžΆαž“αž‚αŸ’αžšαž”αŸ‹αž‚αŸ’αžšαžΆαž“αŸ‹
αžœαžΆαž’αžΆαž… behave αž‡αžΆ diaphragm αžŠαŸ‚αž›αž˜αžΆαž“ high in-plane stiffness αž”αŸ‰αž»αž“αŸ’αžαŸ‚αž™αžΎαž„αž“αŸ…αžαŸ‚αžαŸ’αžšαžΌαžœαž–αž·αž“αž·αžαŸ’αž™ geometry, openings αž“αž·αž„ diaphragm flexibilityαŸ”
@αž’αŸ’αž“αž€αžαžΆαž˜αžŠαžΆαž“

08/08/2026

Design structure & Typical drawing
Project TKC mall
Contact: t.me/DCStructure168

01/08/2026

D&C Structure Design

Sway frame column design. Follow for more File in channel: t.me/dcstructuresharingknowledge
01/08/2026

Sway frame column design.
Follow for more
File in channel: t.me/dcstructuresharingknowledge

Column_Design_Rectangular_Section_Non_Sway_FrameJoint Telegram for knowledge: t.me/dcstructuresharingknowledge
30/07/2026

Column_Design_Rectangular_Section_Non_Sway_Frame

Joint Telegram for knowledge: t.me/dcstructuresharingknowledge

30/07/2026
πŸ«αž‚αž˜αŸ’αžšαŸ„αž„αž’αžΆαž αžΆαžšαžŠαŸ’αž‹αžΆαž“ πŸ«αžŠαŸ‚αž›αžŸαž·αž€αŸ’αžŸαžΆαžšαž”αŸ’αž›αž„αŸ‹αž‚αŸ’αžšαŸ„αž„αž•αŸ’αž‚αž»αŸ†αžŠαŸ„αž™ D&C Strucuture Desgin.πŸ‘‰αžŸαžΌαž˜αž‘αŸ†αž“αžΆαž€αŸ‹αž‘αŸ†αž“αž„αž˜αž€αž€αžΆαž“αŸ‹αž™αžΎαž„αžαŸ’αž‰αž»αŸ†αžŸαž˜αŸ’αžšαžΆαž”αŸ‹αžšαžΆαž›αŸ‹αž€αžΆαžšαž„αžΆαžšαŸ–   Β»...
30/07/2026

πŸ«αž‚αž˜αŸ’αžšαŸ„αž„αž’αžΆαž αžΆαžšαžŠαŸ’αž‹αžΆαž“ πŸ«αžŠαŸ‚αž›αžŸαž·αž€αŸ’αžŸαžΆαžšαž”αŸ’αž›αž„αŸ‹αž‚αŸ’αžšαŸ„αž„αž•αŸ’αž‚αž»αŸ†αžŠαŸ„αž™ D&C Strucuture Desgin.
πŸ‘‰αžŸαžΌαž˜αž‘αŸ†αž“αžΆαž€αŸ‹αž‘αŸ†αž“αž„αž˜αž€αž€αžΆαž“αŸ‹αž™αžΎαž„αžαŸ’αž‰αž»αŸ†αžŸαž˜αŸ’αžšαžΆαž”αŸ‹αžšαžΆαž›αŸ‹αž€αžΆαžšαž„αžΆαžšαŸ–
Β» αžŸαž·αž€αŸ’αžŸαžΆ αž“αž·αž„αž‚αžŽαž“αžΆαž‚αŸ’αžšαžΏαž„αž•αŸ’αž‚αž»αŸ†αžŸαŸ†αžŽαž„αŸ‹ (Structural Design)
Β» αž‚αžΌαžšαž”αŸ’αž›αž„αŸ‹αž›αž˜αŸ’αž’αž·αžαžŸαžšαžŸαŸƒαžŠαŸ‚αž€αžŸαž˜αŸ’αžšαžΆαž”αŸ‹αžŸαžΆαž„αžŸαž„αŸ‹ (Structural Drawing)
Β» αžŸαž·αž€αŸ’αžŸαžΆ αž“αž·αž„αž–αž„αŸ’αžšαžΉαž„αž›αžΎαž‚αŸ’αžšαžΏαž„αž•αŸ’αž‚αž»αŸ†αžŸαŸ†αžŽαž„αŸ‹αž’αžΆαž‚αžΆαžšαž…αžΆαžŸαŸ‹αŸ— (Strengthening Structure)
Β» αž‚αžŽαž“αžΆβ€‹αž”αžšαž·αž˜αžΆαžŽ αž“αž·αž„αžšαŸ€αž”αž…αŸ† BOQ
αž‘αŸ†αž“αžΆαž€αŸ‹αž‘αŸ†αž“αž„αžαžΆαž˜αžšαž™αŸ‡ t.me/DCStructure168
Joint Telegram for knowledge : t.me/dcstructuresharingknowledge
#αž—αžΌαž˜αž·αž‚αŸ’αžšαžΊαŸ‡

FIDIC BASICS FOR QUANTITY SURVEYORSDid you know that most variations, claims, extensions of time (EOT), and payment disp...
11/07/2026

FIDIC BASICS FOR QUANTITY SURVEYORS

Did you know that most variations, claims, extensions of time (EOT), and payment disputes in construction projects are governed by contract provisions?

That is why understanding FIDIC is one of the most important skills for every Quantity Surveyor.

FIDIC (FΓ©dΓ©ration Internationale Des IngΓ©nieurs-Conseils) is one of the most widely used standard forms of construction contracts worldwide. It provides a structured framework that defines the rights, responsibilities, and obligations of the Employer, Contractor, Engineer, and other project stakeholders.

For Quantity Surveyors, understanding FIDIC is essential because it directly impacts cost management, valuations, variations, claims, EOT assessments, and final account settlement.

πŸ” Why FIDIC Matters
βœ… Clearly Defines Contractual Responsibilities
βœ… Provides Procedures for Variations & Claims
βœ… Supports Fair Risk Allocation
βœ… Improves Contract Administration
βœ… Helps Resolve Disputes Effectively
βœ… Protects Commercial Interes