09/06/2025
Sb constructions new project
For a 200 sq yards
5 storey building
Easy way to understand the drawing
Here's a breakdown of the details:
1. Footing Plan (Top Section of the Image):
* Layout: Shows a grid of columns and beams, indicating the foundation layout.
* Dimensions: Various dimensions are provided in feet and inches (e.g., 13'-3", 6'-6", 3'-4", 10'-7", 10'-4", 10'-10", 6'-6", 5'-0").
* Column Labeling: Columns are labeled as C1, C2, C3, and C4.
* Footing Types: Footings are marked with 'FB/PB' (Footing Beam/Plinth Beam) indicating connections between footings.
* Depth Information: Some footings have notations like "(-6'-0" G.L.)" or "(-6'-0" G.L.) DOUBLE AML" which likely refers to the depth of the footing from the Ground Level (G.L.) and "AML" might mean "Along Main Line" or similar.
* Rectangular Grids: Rectangular outlines around the columns likely represent the actual footings.
2. Column's Schedule (Middle-Left Section of the Image):
This table provides detailed information about each column type:
* NO. (Serial Number): 1, 2, 3, 4, 5, 6.
* SIZE:
* C1: 450x230
* C2: 450x300
* C3: 450x300
* C4: 230x230
* FB: 230x375 (likely refers to Footing Beam)
* PB: 230x375 (likely refers to Plinth Beam)
* MAIN REINF. (Main Reinforcement):
* C1: \phi 16 - 8Nos.
* C2: \phi 20 - 4Nos., \phi 16 - 8Nos. (Total 12 Nos.)
* C3: \phi 16 - 8Nos.
* C4: \phi 16 - 4Nos.
* FB: \phi 16 - 6Nos.
* PB: \phi 16 - 6Nos.
* RINGS TYP. (Rings/Stirrups Type):
* All columns and beams (C1, C2, C3, C4, FB, PB) use \phi 8 rings.
* SEC. (Spacing/Centres):
* All columns and beams have rings spaced at 150 C/C (centres).
3. Column Details (Bottom Section of the Image):
* Typical Section (Internal Wall):
* Shows a section of a brick wall on a PCC (Plain Cement Concrete) foundation.
* PCC LEVEL: Indicated.
* BRICK WALL: Shown with dimensions and details.
* RINGS: \phi 8 - 150 C/C.
* MAIN REINF.: \phi 16 - 8Nos.
* GROUT LEVEL: Indicated.
* CONCRETE GRADE: 1:5:10 PCC.
* LEVELS: Various level lines are shown.
* Typical Section (Outer Column):
* Shows a cross-section of an exterior column from the footing up to the slab.
* SLAB: Indicated at the top.
* RINGS: \phi 8 @ 4" C/C near the slab, and \phi 8 @ 6" C/C for the upper part of the column.
* RINGS: \phi 8 @ 4" C/C near the ground level.
* MAIN REINF.: \phi 16 - 8 Nos.
* GROUT LEVEL: Indicated.
* GROUND LEVEL: Indicated.
* PCC: 1:5:10.
* Footing Details: Shows main reinforcement (\phi 16 - 3 Nos. and \phi 16 - 2 Nos.) in the footing.
* DIMENSIONS: Heights are provided (e.g., 2000, 1000).
* Typical Section (Internal Column):
* Similar to the outer column section but likely for an internal column.
* SLAB: Indicated.
* RINGS: \phi 8 @ 4" C/C near the slab, and \phi 8 @ 6" C/C for the upper part of the column.
* RINGS: \phi 8 @ 4" C/C near the ground level.
* MAIN REINF.: \phi 16 - 8 Nos.
* GROUT LEVEL: Indicated.
* GROUND LEVEL: Indicated.
* PCC: 1:5:10.
* Footing Details: Shows main reinforcement (\phi 16 - 3 Nos. and \phi 16 - 2 Nos.) in the footing.
* DIMENSIONS: Heights are provided (e.g., 2000, 1000).
SB-Constructions
Gurugram
New Project