Indus Solar Power

Call Directions Website Contact the business

Indus Solar Power Since 1996, Manufacturer, Exporter & Service Provider of UPS, Servo Stabilizers, & Tubular Batteries, and Solar Plant Installation & Maintenance Services.

☀️ Power Your Future with Indus Solar Power! Reduce your electricity bills and switch to reliable rooftop solar with Ind...
29/09/2026

☀️ Power Your Future with Indus Solar Power!

Reduce your electricity bills and switch to reliable rooftop solar with Indus Instruments Pvt. Ltd. We provide complete Solar EPC solutions for Residential Societies, Commercial Buildings, Industries & Educational Institutions.

⚡ On-Grid | Off-Grid | Hybrid Solar
🏢 Residential | Commercial | Industrial
🔧 Installation, Monitoring, AMC & O&M Support
☀️ 30+ Years of Solar Experience

📞 Contact: +91 95949 62506 / 95949 62521
📍 Dombivli (East), Thane, Maharashtra

Indus Instruments Pvt. Ltd. | Indus Solar Power.
Powering Savings. Building a Sustainable Future.

How MSEDCL Consumers Can Reduce Demand Charges: A Practical Technical Guide by Indus Solar PowerFor commercial and indus...
26/09/2026

How MSEDCL Consumers Can Reduce Demand Charges: A Practical Technical Guide by Indus Solar Power

For commercial and industrial electricity consumers, the electricity bill is not determined only by the number of units consumed. Maximum Demand (MD) can have a significant impact on the monthly electricity cost, particularly for consumers whose tariff includes demand charges.

Many businesses focus on reducing kWh consumption but overlook the fact that a short-duration peak in electrical demand can increase the monthly bill. Therefore, effective demand management should be an important part of every commercial and industrial consumer's energy-saving strategy.

This article explains what demand charges are, why maximum demand increases, and the practical measures that MSEDCL consumers can take to reduce them.

1. What Are Demand Charges?

Demand charges are charges based on the electrical demand recorded by the consumer during the billing period, according to the applicable tariff and billing methodology.

For a simplified example:

Maximum Demand = 500 kVA

Demand Charge Rate = ₹600/kVA

Then:

Demand Charge = 500 × ₹600 = ₹3,00,000 per month
If the consumer can reduce the maximum demand to 400 kVA:

400 × ₹600 = ₹2,40,000 per month
Potential reduction:
₹60,000 per month
or approximately:
₹7.20 lakh per year

The actual calculation must always be made using the applicable MSEDCL tariff, billing rules, minimum-demand provisions, penalties and other applicable charges.

2. Maximum Demand Is Not the Same as Energy Consumption
This is one of the most important concepts.
Energy consumption is measured in kWh (units), while electrical demand may be measured in kW or kVA, depending on the applicable tariff and metering arrangement.

Consider two factories that each consume approximately 1,00,000 units in a month.

Factory A operates its equipment relatively evenly throughout the day.

Factory B operates several large machines simultaneously for a short period.

Both may consume similar monthly energy, but Factory B can have a significantly higher maximum demand.

Therefore:
Reducing energy consumption and reducing maximum demand are two different energy-management objectives.

3. First Find Out When the Maximum Demand Occurs

Before investing in any equipment, analyse the consumer's demand profile.

Modern meters can provide interval-wise data, commonly including 15-minute demand intervals.

For example:
Time - Demand

9:00 AM - 280 kVA

11:00 AM - 320 kVA

1:00 PM - 350 kVA

2:15 PM - 500 kVA

3:00 PM - 340 kVA

The important question is:
Why did demand suddenly reach 500 kVA at 2:15 PM?

Perhaps:
A large compressor started.

A chiller started.
Several pumps operated simultaneously.
Multiple motors were started together.
EV charging started.
HVAC load increased.

Identifying the cause of the peak is the first step towards reducing demand charges.

4. Avoid Simultaneous Operation of Large Loads

One of the simplest demand-reduction techniques is load staggering.

Suppose a facility has:

Compressor – 150 kW

Chiller – 120 kW

Pumps – 80 kW

HVAC – 100 kW

If all equipment operates simultaneously, the electrical demand can increase substantially.

Instead, the consumer can schedule the equipment so that non-critical loads do not operate simultaneously.

For example:

10:00 AM – Compressor

10:15 AM – Chiller

10:30 AM – Pumps

This may reduce the peak demand without significantly affecting total production.

5. Install an Automatic Demand Controller

An Automatic Demand Controller continuously monitors electrical demand.
For example, suppose the desired demand limit is 400 kVA.
When demand approaches the programmed limit, the controller can temporarily disconnect selected non-critical loads such as:

Water heaters
Auxiliary pumps
HVAC equipment
Battery chargers
EV chargers
Non-essential compressors
Once demand falls, these loads can be restored automatically.

This provides much better control than relying entirely on manual switching.

6. Improve Power Factor

Power factor is particularly important where billing demand is related to kVA.

The basic relationship is:

kVA = kW ÷ Power Factor

For example, if a facility requires 500 kW:

At PF = 0.80:
500 ÷ 0.80 = 625 kVA
At PF = 0.95:
500 ÷ 0.95 = 526 kVA

Therefore, improving power factor can reduce the apparent-power requirement for the same real power.

Consumers may use properly designed APFC panels to maintain an appropriate power factor.

However, capacitor banks should not be oversized. Harmonics, resonance and leading power factor must be considered. A proper electrical and power-quality study should be carried out before modifying the capacitor system.

7. Control Motor Starting Demand

Large motors can create high starting currents and temporary demand peaks.

Industries with compressors, pumps, chillers, conveyors and other large motors should consider appropriate starting methods such as:

Variable Frequency Drives (VFDs)
Soft starters
Sequential motor starting
Proper motor control systems
VFDs can also reduce energy consumption in suitable variable-speed applications such as pumps and fans.

8. Shift Flexible Loads

Not every electrical load needs to operate at the same time.

Loads such as:

EV charging
Water pumping
Battery charging
Certain heating processes
Non-critical HVAC
Some production processes

can potentially be shifted to periods when the facility's demand is lower.

For example, instead of charging ten EVs simultaneously at 20 kW each:

10 × 20 = 200 kW

charging can be staggered to avoid adding the entire 200 kW to the facility's peak demand.

9. Use Solar Strategically

Rooftop solar can reduce grid electricity consumption during daylight hours.

For example:

Facility load = 500 kW

Solar output = 150 kW

Potential grid requirement:

500 − 150 = 350 kW

However, solar does not automatically guarantee an equivalent reduction in billed maximum demand. The actual benefit depends on the timing of the demand peak, solar output, metering arrangement and applicable tariff.

Therefore, solar should be designed based on the actual load profile, not only annual electricity consumption.

10. Battery Energy Storage for Peak Shaving

For consumers with short-duration demand peaks, a Battery Energy Storage System (BESS) can be considered.

Suppose:

Facility demand = 550 kW

Target grid demand = 450 kW

The battery can provide:

550 − 450 = 100 kW

during the peak period.

If the peak lasts two hours:

Required energy ≈ 100 × 2 = 200 kWh

Actual BESS sizing must consider battery usable capacity, depth of discharge, efficiency, degradation, reserve SOC, PCS rating and operating conditions.

The objective is called peak shaving, using the battery to reduce the highest grid demand.

11. Review Contract Demand

Contract Demand and Maximum Demand are not necessarily the same.

For example:

Contract Demand = 1,000 kVA

but the facility may consistently operate around:

450–550 kVA

In such a case, the consumer may consider whether the contracted capacity is appropriate under the applicable tariff and minimum-billing provisions.

However, Contract Demand should not be reduced simply because the current month's demand is low. At least 12 months of demand data, future expansion plans and operational requirements should be considered.

12. A Practical Demand-Reduction Strategy

For most commercial and industrial consumers, the recommended sequence is:

Measure → Analyse → Identify Peak → Find Cause → Stagger Loads → Improve PF → Shift Flexible Loads → Automate Control → Evaluate Solar/BESS

Before investing in expensive equipment, consumers should first identify the exact source and timing of their demand peak.

Conclusion

Reducing MSEDCL demand charges is not simply about using less electricity. It is about using electricity intelligently and controlling the highest demand created during the billing period.

A professional energy audit should examine:

Maximum Demand
Contract Demand
kWh consumption
kVA/kW profile
Power Factor
Time-of-Day consumption
Solar generation and self-consumption
Export and import
Major electrical loads
Demand penalties or applicable incentives
Potential for load shifting
Solar and BESS opportunities

The most economical solution is often not a major capital investment. Better scheduling, staggered equipment operation, power-factor correction, automated demand control and intelligent load management can sometimes reduce peak demand significantly.

For larger consumers, combining Energy Monitoring + EMS + APFC + Solar + BESS + Automated Load Control can create an integrated demand-management strategy that reduces electricity costs while improving overall energy efficiency.

Remember: Don't only ask, "How many units are we consuming?" Ask, "When are we consuming them, and what is creating our maximum demand?"

That question is often the starting point for significant electricity-bill savings.

Need Expert Support to Reduce Your Demand Charges?

Many commercial and industrial consumers pay higher electricity bills not because of excessive energy consumption, but because of avoidable peak demand, poor load management, low power factor, or an incorrectly optimized electrical system.

Identifying these opportunities requires more than reviewing the monthly bill. It requires a detailed technical analysis of:

Maximum Demand (kW/kVA) profile
Contract Demand utilization
Power Factor performance
Time-of-Day (ToD) consumption pattern
Major load operation
Solar self-consumption and export analysis
Demand penalties and billing structure
Peak-shaving opportunities through load scheduling, APFC, VFDs, EMS, Solar and BESS

A professional demand-management study can help consumers understand:

-Why demand peaks occur

-Which equipment contributes to maximum demand

-How much demand can realistically be reduced

-The expected annual savings

-The technical and financial feasibility of improvement measures

Our technical team provides:

Electricity bill analysis
Demand and load profile studies
Contract Demand optimization studies
Power Factor and APFC assessment
Solar and Battery Energy Storage (BESS) feasibility studies
Energy audits for commercial and industrial facilities
Customized demand reduction strategies

Every facility has a unique load pattern. Therefore, the most effective solution is not a standard recommendation, but a data-driven approach based on actual operating conditions.

If your organization would like to reduce electricity costs, improve energy efficiency, and optimize demand charges, a detailed technical assessment is the first step.

Contact us today for a professional electricity bill analysis and demand optimization study to identify potential savings and build a practical roadmap for reducing your energy costs.

Connect with Indus Solar Power Today
Website: www.indussolarpower.com
Address: W-246 A, MIDC Phase II, Dombivli (E), Maharashtra
Contact: +91 95949 62506 / 93728 03828
Email: [email protected]

“Power Your Business with the Sun. Save More. Grow Smarter.”

About the Author

Since 1996, Indus Powers has been a trusted name in high-quality digital UPS, DSP sine wave UPS, static UPS, online UPS, lift UPS, and servo stabilisers, along with tubular batteries and transformers.

Indus Solar Power is a leading solar EPC company delivering high-quality rooftop solar solutions for residential, commercial, industrial, government, educational, and housing society projects across Maharashtra. With 30+ years of expertise, we have successfully installed solar power plants for factories, colleges, schools, hospitals, government organisation, commercial establishments, and residential communities.

From system design and installation to net metering and AMC support, Indus Solar Power provides end-to-end solar solutions that help customers reduce electricity bills, Maximize savings, and achieve energy independence through clean and sustainable energy.

Indus is a Trusted Solar EPC Partner in Mumbai, Thane & Navi Mumbai. Powering Maharashtra with trusted Solar & Power Conditioning Solutions, proudly serving 10 Lakh+ customers across the state since 1996.

Indus Solar Power - Best Solar EPC Company in Mumbai, Thane and Navi Mumbai.

🙏 गणपती बाप्पा मोरया! 🌺As we bid farewell to Bappa, we carry forward His blessings, positivity, and new energy into the ...
25/09/2026

🙏 गणपती बाप्पा मोरया! 🌺
As we bid farewell to Bappa, we carry forward His blessings, positivity, and new energy into the year ahead.

May Lord Ganesha bless the Indus Solar Power & Indus Instruments family with greater success, new opportunities, happiness, and prosperity.

☀️ From powering homes and businesses to powering dreams, may the coming year be brighter, stronger, and more successful!

Thank you, Bappa, for the blessings. See you again next year!
🌿 Ganpati Bappa Morya! Pudchya Varshi Lavkar Ya! 🙏

-Team Indus Solar Power & Indus Instruments

20/09/2026

⚡ A, B, C & D TOD Zones Explained!

Did you know that the time when you consume electricity can affect your electricity bill? 💡

In our latest video, we break down TOD (Time of Day) Tariff and explain how different A, B, C & D TOD zones can impact your electricity costs.

🔍 In this video, you'll understand:
✅ What are A, B, C & D TOD zones?
✅ How does TOD tariff work?
✅ Why energy consumption timing matters for bill optimisation?

For commercial and industrial solar consumers, understanding your electricity consumption pattern is just as important as understanding your solar generation.

☀️ Generate Smart. Consume Smart. Save More.

🎥 Watch the full video to understand TOD billing in simple terms.

⚙️🔧 Dedicated Minds, Bold Ideas, Powerful Innovations.This Engineers’ Day, we salute the engineers who transform complex...
15/09/2026

⚙️🔧 Dedicated Minds, Bold Ideas, Powerful Innovations.

This Engineers’ Day, we salute the engineers who transform complex challenges into reliable solutions and continuously push the boundaries of innovation. 💡⚡

At Indus Instruments, engineering drives everything we do from power protection to dependable electrical solutions built for real-world performance.

Celebrating the minds that engineers progress. Happy Engineers’ Day! 👷‍♂️⚙️

🙏🌺 Bappa Has Arrived, Bringing Blessings, Prosperity & Positive Energy! 🐘✨This Ganesh Chaturthi, may Lord Ganesha remove...
13/09/2026

🙏🌺 Bappa Has Arrived, Bringing Blessings, Prosperity & Positive Energy! 🐘✨

This Ganesh Chaturthi, may Lord Ganesha remove every obstacle, fill your homes and businesses with happiness, and bless you with success, prosperity & endless opportunities. 🌟

☀️ From powering your homes with clean solar energy to keeping your businesses powered with reliable power solutions, for we’re proud to power your journey. ⚡💚

🌿 May Bappa’s blessings bring brighter beginnings and a more sustainable tomorrow!

🎉 Wishing all our customers, partners, friends & well-wishers a very Happy Ganesh Chaturthi! 🙏❤️

Ganpati Bappa Morya! 🐘🌺

SolarEnergy CleanEnergy PowerSolutions SustainableFuture

Top 5 Solar Inverter Error Codes & How to Fix Grid Tripping Problems by Indus Solar Power - Best Solar EPC Company in Mu...
09/09/2026

Top 5 Solar Inverter Error Codes & How to Fix Grid Tripping Problems by Indus Solar Power - Best Solar EPC Company in Mumbai, Navi Mumbai & Thane.

A rooftop solar system is engineered to run automatically day after day, converting clean sunlight into electricity. However, when your solar inverter suddenly shows a red fault light or constantly trips during peak sunny hours, your unit's generation drops to zero, costing you money every minute.

Most inverter faults are not hardware breakdowns; they are built-in safety protective shutdowns triggered by grid fluctuations, wiring faults, or voltage imbalances.

In this practical troubleshooting guide by Indus Solar Power, we explain the top 5 solar inverter error codes, what they mean, and how to fix grid tripping issues safely.

1. Error Code: Grid Overvoltage (OV-G / Grid Voltage High)

What It Means:
This is the single most common cause of inverter and MCB tripping during daytime. By safety standards, on-grid inverters must synchronise with the DISCOM grid voltage. If the local grid voltage rises above the statutory threshold (typically ~253V to 270V depending on DISCOM parameters), the inverter disconnects to prevent damage.

Common Causes:
-Peak generation in local neighbourhoods pushing transformer voltage up.
-Undersized AC cabling between the inverter and the main meter causing internal line voltage drops.
-DISCOM distribution transformer tapping set too high.

How to Fix It:

-Check AC Cable Sizing: Ensure the AC cable from your inverter to the meter has adequate cross-sectional area to minimise line resistance.
-Phase Shifting (for 1-Phase Systems): If you are on a single-phase connection, request your electrician or DISCOM to shift your line to a phase with lower baseline voltage.
-Log a DISCOM Request: Contact your local utility office to calibrate the distribution transformer tap setting if area-wide voltage is constantly high.



2. Error Code: PV Isolation Low / Ground Fault (ISO Fault)

What It Means:
The inverter has detected a breakdown in insulation resistance on the DC side (between the solar panels/wiring and the ground). In simple terms, current is leaking toward the mounting structure or earth.

Common Causes:
-Damaged, cracked, or rodent-bitten DC cables touching the metal structure.
-Moisture, rain, or dew entering unsealed MC4 connectors.
-Poor waterproofing in the DC array junction box.

How to Fix It:

-Visual Cable Inspection: Check the DC cable runs beneath the panel structure for chafing, sharp metal edges, or cuts.
-Inspect MC4 Connectors: Ensure all solar connector plugs are crimped with professional tools and have intact IP67/IP68 rubber weather seals.
-Dry Out Array: If the fault occurs only on humid mornings and disappears once the sun dries the moisture, unsealed connections or cracked backsheets must be identified and resealed.

3. Error Code: No Grid / Grid Loss (Grid Absent)

What It Means:
Your on-grid solar inverter does not detect an active AC voltage supply from the electricity board. For anti-islanding safety compliance, on-grid systems must shut down immediately when the main power grid goes down.

Common Causes:
-Genuine power outage (load shedding) in your area.
-The AC miniature circuit breaker (MCB) or moulded case circuit breaker (MCCB) in your ACDB has tripped.
-Blown utility fuses or loose terminal screws on the AC side.

How to Fix It:

-Check Grid Power: Confirm if normal grid power is available to your property.
-Check ACDB Breakers: Open the ACDB box and verify that the solar AC MCB is switched to the "ON" position.
-Verify Terminal Connections: Have a qualified technician inspect and tighten any loose screw terminals inside the AC distribution board.

4. Error Code: Inverter clipping fault

What It Means:
When your solar panels produce more power than your inverter can handle, the extra energy gets capped; this is known as inverter clipping.

Common Causes:
-Incorrect string design (too many solar panels connected in series in a single string).
-Cold winter mornings, where low temperatures cause panel voltages to rise naturally beyond standard test conditions (STC).

How to Fix It:

Redistribute the String: Reconfigure the module strings into balanced parallel circuits or split panels across two MPPT trackers.
Recalculate Temperature Coefficients: Ensure your installer calculates the cold-temperature open-circuit voltage before commissioning.

5. Error Code: Over-Temperature Fault (Inverter Overheat)

What It Means:
The internal temperature of the inverter’s heat sink or power electronics has exceeded safe thermal operating limits, causing the system to derate its power or shut down completely.

Common Causes:
-Inverter installed under direct, scorching sunlight without a canopy.
-Blocked ventilation slots or malfunctioning external cooling fans.
-Inadequate clearance around the inverter walls.
-Inverter overloading

How to Fix It:

Install a Solar Inverter Canopy: Always mount the inverter in the shade, or install a protective sheet canopy if mounted outdoors on the terrace.
Maintain Clearance: Leave at least 30 to 50 cm of open space on all sides of the inverter for natural convection airflow.
Clean Heatsinks: Periodically clear dust, cobwebs, and debris from the cooling fins on the back of the inverter.
Right Panel-to-Inverter Ratio: Maintain the right balance between solar panel capacity and inverter capacity to prevent inverter overloading.

When Should You Call a Professional?

While basic checks (like verifying if an AC breaker tripped or clearing dust around cooling vents) can be done by owners, high-voltage DC and AC circuits should never be touched without professional safety gear. Working with live DC voltages from solar arrays carries high electrical risk.

At Indus Solar Power, we provide complete remote monitoring, plant health audits, and professional troubleshooting to keep your rooftop solar system generating at peak efficiency year-round.

Keep Your Solar Plant Generating at 100%

Facing recurring inverter errors or frequent grid tripping? Contact the engineering team at Indus Solar Power today for swift technical diagnostics and plant maintenance services!

Connect with Indus Solar Power Today

Website: www.indussolarpower.com

Address: W-246 A, MIDC Phase II, Dombivli (E), Maharashtra
Contact: +91 95949 62506 / 93728 03828
Email: [email protected]
“Power Your Business with the Sun. Save More. Grow Smarter.”

About the Author

Since 1996, Indus Powers has been a trusted name in high-quality digital UPS, DSP sine wave UPS, static UPS, online UPS, lift UPS, and servo stabilisers, along with tubular batteries and transformers.

Inndus Solar Power is a leading solar EPC company delivering high-quality rooftop solar solutions for residential, commercial, industrial, government, educational, and housing society projects across Maharashtra. With 30+ years of expertise, we have successfully installed solar power plants for factories, colleges, schools, hospitals, government organisations, commercial establishments, and residential communities.

From system design and installation to net metering and AMC support, Indus Solar Power provides end-to-end solar solutions that help customers reduce electricity bills, maximise savings, and achieve energy independence through clean and sustainable energy.

Indus is a Trusted Solar EPC Partner in Mumbai, Thane & Navi Mumbai. Powering Maharashtra with trusted Solar & Power Conditioning Solutions, proudly serving 10 Lakh+ customers across the state since 1996.

Indus Solar Power - Best Solar EPC Company in Mumbai, Thane and Navi Mumbai.

Trusted Solar Expertise Since 1996 For over 30+ years, Indus Solar Power has been delivering reliable solar energy and p...
08/09/2026

Trusted Solar Expertise Since 1996
For over 30+ years, Indus Solar Power has been delivering reliable solar energy and power solutions for residential, commercial & industrial customers across Maharashtra.

🌞 Why Choose Indus Solar Power?
✅ 30+ Years of Industry Experience
✅ 5MW+ Rooftop Solar PV Installed
✅ Expert & Skilled Technical Team
✅ Premium-Quality Solar Materials
✅ Hot-Dip Galvanized & Cyclone-Resistant Structures
✅ 5-Year Energy Generation Guarantee
✅ Zero Repair Cost Assurance for 5 Years*
✅ Power Boost Maintenance Program
✅ Performance Compensation Guarantee
✅ On-Grid | Off-Grid | Hybrid Solar Solutions
✅ Complete End-to-End Solar Installation & Support

💡 Our Promise:
Solar is not just a product. It’s a performance commitment.

📍 Serving: Mumbai | Thane | Navi Mumbai | Kalyan-Dombivli | Panvel | Raigad | Pune | Nashik & more

📞 Call: +91 95949 62506 / +91 95949 62509
📧 Email: [email protected]
🌐 Visit: indussolarpower.com
📍 Corporate Office: W-246 A, M.I.D.C., Phase II, Nr. Abhinav Vidyalay, Dombivli (E), Thane – 421203
☀️ Switch to Solar, Save More, Power Your Future with Indus.

04/09/2026

How to Read an MSEDCL LT Industrial Solar Bill? TOD Billing, GSC & Load Shifting Explained by Indus Solar Power

Simply looking at your solar generation is not enough.
For an LT Industrial Solar Consumer, you need to understand your Imported Units, Adjusted Units, Billed Units, Power Factor, kVAh, Demand Charges, TOD Billing, Solar Generation and Grid Support Charges (GSC).

In this video, we explain how to read an MSEDCL LT Industrial Solar Bill using an actual bill-analysis example.

In this video, you will learn:
✅ How to identify Imported Units
✅ How Adjusted Units and Billed Units are calculated
✅ How to calculate Actual Electricity Consumption
✅ Difference between kWh and kVAh
✅ Why Power Factor is important
✅ What is TOD – Time of Day Billing?
✅ Which TOD period has a lower electricity rate
✅ How to identify expensive consumption periods
✅ How to shift flexible factory loads to appropriate time zones
✅ How solar generation affects your electricity bill
✅ What is Grid Support Charge (GSC)?
✅ How to calculate the overall impact of solar on your bill
✅ How Solar + TOD Optimization + Load Shifting can help reduce electricity costs

📊 Example Used in This Video
Imported Units: 50,270 kWh
Adjusted Units: 1,645 kWh
Billed Units: 48,625 kWh
Power Factor: 0.95
Billed Consumption: 51,184 kVAh
Solar Generation: 19,164 units
Actual Electricity Use

The example calculates actual electricity consumption as:
Actual Electricity Use = Generation + Imported Units + Previous Banked Units − Exported Units − Current Banked Units

Therefore:
= (19,164 + 50,270) − 1,645
= 67,789 kWh
At a Power Factor of 0.95:
67,789 ÷ 0.95 = 71,357 kVAh
These figures are taken from the attached bill analysis.

⏰ TOD Billing Example
The example shows different electricity charges for different time zones:
12 AM – 9 AM: ₹10.53/unit
9 AM – 5 PM: ₹9.39/unit
5 PM – 12 AM: ₹12.45/unit

This means electricity does not cost the same throughout the day.
Where the manufacturing process permits, flexible loads such as compressors, pumps, chillers and other shiftable loads can potentially be moved from higher-cost periods to lower-cost periods.
The analysis specifically highlights the 9 AM–5 PM period as the lower-cost zone in this example.

☀️ Grid Support Charge – GSC
The example uses a GSC of ₹1.96/unit.
For 19,164 units of solar generation:
19,164 × ₹1.96 ≈ ₹37,561
Therefore, when calculating the financial benefit of solar, applicable charges should also be considered—not just solar generation.

💰 Example Financial Impact
Without Solar: ₹7,70,780
With Solar: ₹5,95,736
Net Saving: ₹1,74,944/month
This is the saving shown in the attached bill analysis example.
Important: This is a specific bill-analysis example. Actual savings will depend on the consumer's tariff category, consumption pattern, TOD applicability, solar generation, demand, power factor and applicable charges.

























Address

1, Ground Floor, Abhang, Agarkar Road, Near Hotel Modern Cafe
Dombivli
421306

Opening Hours

Monday 9am - 9pm
Tuesday 9am - 9pm
Wednesday 9am - 9pm
Thursday 9am - 9pm
Friday 9am - 9pm
Saturday 9am - 9pm

Telephone

+919594962506

Alerts

Be the first to know and let us send you an email when Indus Solar Power posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Indus Solar Power:

Shortcuts

Share