Great progress on one of our school decarbonisation projects, with the new low-carbon heating system now taking shape.Th...
27/07/2026

Great progress on one of our school decarbonisation projects, with the new low-carbon heating system now taking shape.

The works include the installation of new air source heat pumps, thermal stores, pumps, controls and associated distribution pipework, replacing the existing heating arrangement with a more efficient system designed to reduce the school’s carbon emissions and improve long-term energy performance.

Externally, the new plant is being housed within a purpose-designed acoustic enclosure to minimise noise impact on the school and surrounding properties while maintaining the airflow and access required for operation and maintenance.

There is still further installation, insulation, commissioning and enclosure work to complete, but it is great to see the plantroom and external installation progressing well.

A strong team effort from everyone involved in delivering the project safely and around the operational requirements of the school.

Great to reach Practical Completion on another successful school heating replacement project.This scheme delivering a hi...
08/03/2026

Great to reach Practical Completion on another successful school heating replacement project.

This scheme delivering a high-performance, future-ready heating solution, achieving the quality and control standards expected on modern education projects.

The system incorporates Crane Dominator valves complete with ACTCS1 Smart Actuators, providing full Modbus/BACnet integration. These actuators enable precise modulation of flow to match the exact building demand, optimising comfort while driving down energy consumption.

All equipment is controlled via a bespoke BMS panel, ensuring coordinated operation of plant, pumps and SPC FCU convector fans. The result is one of the most comprehensively controlled systems we have delivered to date, with real-time feedback and intelligent energy management at its core.

The heating distribution has been designed to operate at a 45°C flow temperature, positioning the school for a straightforward transition to Air Source Heat Pumps in the future and supporting long-term decarbonisation objectives.

A strong team effort from design through to commissioning has ensured the school now benefits from an efficient, responsive and future-proof heating system — providing a comfortable learning environment while significantly improving overall system performance.

Address

4 Parkyn Road, Daybrook
Nottingham
NG56BG

Opening Hours

Monday 7:30am - 5pm
Tuesday 7:30am - 5pm
Wednesday 7:30am - 5pm
Thursday 7:30am - 5pm
Friday 7:30am - 5pm

Telephone

+441159133333

Alerts

Be the first to know and let us send you an email when Miller Freeman & Sons Nottingham Ltd. posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Miller Freeman & Sons Nottingham Ltd.:

Shortcuts

Share

Category