Be Cool Refrigeration

Be Cool Refrigeration Be Cool Refrigeration & Air-Conditioning
We Repair | We Maintain | We Install
(1)

27/04/2026

We don't work behind closed doors. Before we touch anything, we show our customers exactly what we've foundt: the dust, the blockage, the problem. No surprises on the invoice. That's the BeCool promise.

27/04/2026

We don't work behind closed doors. Before we touch anything, we show our customers exactly what we've found: the dust, the blockage, the problem. No surprises on the invoice. That's the BeCool promise.

Most cold room content shows the inside. Here's the other side of the wall.Two Danfoss Optyma Slim Pack condensing units...
22/04/2026

Most cold room content shows the inside. Here's the other side of the wall.
Two Danfoss Optyma Slim Pack condensing units installed on gravel outside the building — one sized for chiller duty, one for freezer. Perforated cable tray run along the exterior wall for clean cable management. Emergency stop and isolator fitted. Copper pipework brazed and routed through to the evaporators.
Unit spec: OP-LSQM067LLW05E. 400V 3-phase, 50Hz. IP54 rated. LBP application. Manufactured 2025.
Full design, supply, install and commissioning by BeCool Refrigeration.

Cold room install, behind the build.Most people only see the finished product. Here's what goes into it before handover....
17/04/2026

Cold room install, behind the build.
Most people only see the finished product. Here's what goes into it before handover.
GB Controls panel schematic designed for defrost heaters, solenoid valves, fan circuits, and door heaters. Güntner evaporator wiring mapped terminal by terminal. Insulated panels sealed. Checker plate flooring laid. Then the evaporator goes from floor to ceiling brackets.
Every wire routed to spec. Every connection documented. Nothing left to guesswork.
Full design, supply, install and commissioning by BeCool.
Link in bio.

Dual cold room installation, walk-in chiller and freezer built from the ground up.Insulated panel construction. Güntner ...
06/04/2026

Dual cold room installation, walk-in chiller and freezer built from the ground up.
Insulated panel construction. Güntner evaporators sized for each room's duty. Copper pipework brazed and pressure-tested. Freddox digital controllers with defrost logic and alarm monitoring. PVC strip curtains fitted. Checker plate flooring in the freezer. Stainless steel racking in the chiller.
Both rooms commissioned and holding temperature — chiller at 3.0°C, freezer at −8.1°C.
Full design, supply, install and commissioning by BeCool.
Book Now. Link in bio.

06/04/2026

Fresh commissioning on two outdoor units today, one ground-level, one rooftop Samsung. Electrical checks, vacuum pull, pressure test, and full gas charge. Every valve torqued, every reading documented. That's the BeCool standard.

Refrigeration fit-out, from condensing units to commissioning.This carousel covers the full mechanical install for a dua...
02/04/2026

Refrigeration fit-out, from condensing units to commissioning.
This carousel covers the full mechanical install for a dual cold room system built in an existing basement unit. External Danfoss Optyma condensing units feed insulated copper lines routed overhead into both rooms, each fitted with Güntner evaporators, GB Controls panels and alarm systems.
Scope of work:
→ External cable tray and wall penetrations
→ Danfoss Optyma condensing units on anti-vibration mounts
→ Insulated refrigerant pipework routed overhead
→ Copper brazing to evaporator connections
→ Güntner evaporator mounting (single & dual fan)
→ GB Controls evaporator panel + isolator
→ Alarm and safety systems
→ Full commissioning and handover
Designed, installed and commissioned by BeCool Refrigeration.

31/03/2026

This Mitsubishi VRF system was throwing fault codes. Our technician stripped it back to board level, tested every sensor, checked compressor winding resistance, and traced the fault to a single connector. Fixed on-site. That's the BeCool standard

Dual cold rooms built from a bare basement to a complete structure.This project required two interconnected walk-in cold...
22/03/2026

Dual cold rooms built from a bare basement to a complete structure.
This project required two interconnected walk-in cold rooms built within an existing commercial basement. Challenges included working below a concrete soffit with limited headroom and coordinating a multi-room layout with walk-through access.
Scope of work:
→ NAV System insulated panel assembly
→ Aluminium checker plate flooring
→ Interconnecting doorway between both rooms
→ Heavy-duty hinged cold room doors with safety release
→ Full structural build ahead of refrigeration fit-out
Structure complete and ready for commissioning. Refrigeration install to follow.

20/03/2026

Your AC's outdoor unit is doing the heavy lifting — when was the last time someone actually checked it? 🧊 BeCool technicians diagnose before they fix. Book a service. Link in bio.

Address

London
EC4M7JN

Alerts

Be the first to know and let us send you an email when Be Cool Refrigeration posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Be Cool Refrigeration:

Featured

Share