Heat Smart Heating & Renewables

Directions Website Contact the business

Heat Smart Heating & Renewables We have just undertaken a rebrand and will be trading as Heatsmart Heating & Renewables from now on.

Established in 2003 and originally named Darren Russell plumbing but now specialising in the installation of heat pumps, renewables and controls.

The importance of flushing heating systems can often be overlooked as an extra expense.The reality is if not carried out...
19/09/2026

The importance of flushing heating systems can often be overlooked as an extra expense.

The reality is if not carried out with any new boiler installed the expense will eventually mean major failure and loss of efficiency.

This was just a small system but amazed by how much was collected.

https://youtube.com/shorts/0YxcDZHbj7Y?is=0Dttenrkqi3wwYrK

Flushing is something that is as important as the installation itse...

07/08/2026

Full installation walk through video of a new Vaillant Arotherm plus with cylinder, power tank, underground pipe work, UFH, pipe work alterations and all monitored on OEM Heat Geek Vaillant Darren Russell Lee Tapping

Thanks to Ashley Stokes and the team at the Renewable Store for a couple of great days training on the Austrian 🇦🇹 Helio...
31/07/2026

Thanks to Ashley Stokes and the team at the Renewable Store for a couple of great days training on the Austrian 🇦🇹 Heliotherm heat pumps.

Really looking forward to fitting one in the real world to see how they perform.

Scop of 5 and above seem the norm on these units if installed, designed and commissioned correctly.

Active cooling on your Arotherm plus heat pump and how to set it up.
26/07/2026

Active cooling on your Arotherm plus heat pump and how to set it up.

Vaillant Arotherm plus that I have now added the cooling/coding plu...

Not quite finished this heat pump installation over on the Calthorpe Estate in Birmingham but we did get it up and runni...
25/07/2026

Not quite finished this heat pump installation over on the Calthorpe Estate in Birmingham but we did get it up and running for the weekend.

Just a small zone of UFH to install and a new hot feed to supply a redundant gravity shower and a bit of lagging to do, oh and connect the OEM so everyone can see how this performs.

Should be finished by Tuesday next week as so far this job has taken 16 man days with another 4 to go.

I’ve really enjoyed the challenge of being responsible for everything on this job including digging 🥵🥵 the trench for the underground pipe work and know every aspect of this heat pumps performance will lie solely with me and the team.

Another Heat Geek design with a minimum guaranteed efficiency of 450% ✅.

Vaillant Arotherm plus 5kw with active cooling✅

Flow supplies underground pre insulated pipe run of 15m to remote locate the heat pump✅

All UFH to run on open loop with UFH to be fully installed downstairs following kitchen extension in spring 2027✅

New Vaillant 300 litre Unistor pure heat pump cylinder ✅

New Sensocomfort controller and outdoor sensor all hardwired at customer request ✅

My Vaillant Gateway for internet app control ✅

New 450 litre power tank with variable speed pump upto 80 litres per minute (pipe size dependent) ✅

New cold supply to allow 90% of all water draw offs to be through the power tank ✅

Open energy monitor to accurately track performance ✅

Smart grid enabled through the new Vaillant AI interface to connect to the Signergy battery storage system✅

Another fossil fuel gas boiler removed ( gas hob to follow with new kitchen extension)✅

New Hager fuse board fully Vaillant compliant ✅

So much work gone into this project for a fantastic customer who really is trying to get this home to the best possible standards of comfort and running costs, MVHR by throughout also.

Another great team effort with my main man Adam grafting as always and doing a lovely job with the pipe work and insulation.

Nat the apprentice for getting on with all the jobs that need doing if not necessarily as enjoyable as doing pipe work.

Big shout out to the team at Maisum Renewables Lee Tapping getting Sean and Ivan on the case to help get this over the line.

Really looking forward to watching the performance over the next 12 months.
Darren Russell

If you are looking for a total solution including remote location of your heat pump then why not get in touch to discuss what’s possible.

Darren On 07950560787 or [email protected]

Did I mention we are currently going through the process of becoming MCS registered so we will have access to other heat pump brands and sizes??

Loving the new Anthracite Vaillant heat pump. Decided to paint the coffins black to match everything up including the pr...
21/07/2026

Loving the new Anthracite Vaillant heat pump. Decided to paint the coffins black to match everything up including the primary pro to finish it off. Heat Geek Darren Russell

16/07/2026

Proper graft for 4days this week installing pre-insulated pipework to remote locate a heat pump.Heat Geek Vaillant

Well what a week that’s been, a first for me and Adam digging a 15m long trench to bury pipe work to remote locate a hea...
16/07/2026

Well what a week that’s been, a first for me and Adam digging a 15m long trench to bury pipe work to remote locate a heat pump over in Harbourne.

Really was a slog but very rewarding as it’s proper graft having to hand dig it all out then put the pipe in which considering it was 180mm duct was more flexible that I expected and went it first time.

All slabs relaid and floors cemented plus heat pump coffins installed ready for next weeks installation.

As always it’s a Vaillant Arotherm plus 5kw in anthracite with active cooling built in, 300 litre Vaillant cylinder with power tank. Also adding and extra room of UFH upstairs using the pre routed caberdek floor.

This system will be on and will be my 3rd on the platform. Heat Geek 450% minimum guaranteed SCOP so hoping to get close to 500% with underfloor and MVHR with a heat loss of 4.77kw.

Can’t wait to get it up and running next week.

Well that’s our first Vaillant Arotherm plus in the new Anthracite finish, with new interface.   Like everything new the...
09/07/2026

Well that’s our first Vaillant Arotherm plus in the new Anthracite finish, with new interface.

Like everything new there is always a little bit of figuring things out like all the plugs that need plugging in and what they do, note to anyone to make sure you plug in S20 with the link in or you get nothing but standby mode.

First time I’ve set up the active cooling as per Heat Geek guidance with a house full of radiators, so will be interesting to see how it helps cool a property down.

Apart from that the interface to the main HIU takes a bit of navigation to get used to where to find readings for commission etc, but like I say once you’ve done the first one things become clearer.

Thanks as always to the team Adam and Nat for plugging away in the heat and Dave from Lloyd electrical (you owe me one)☝️.

Zero disrupt done inside two days with no cylinder upgrade and keeping the system vented.

Minimum guaranteed efficiency of 345% at max flow temp of 54c and hot water store temperature of 48c.

Address

43 Dunnerdaled Road
Clayhanger

Opening Hours

Monday 8am - 6pm
Tuesday 8am - 6pm
Wednesday 8am - 6pm
Thursday 8am - 5pm
Friday 8am - 6pm
Saturday 9am - 2pm

Alerts

Be the first to know and let us send you an email when Heat Smart Heating & Renewables posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Heat Smart Heating & Renewables:

Shortcuts

Share