18/06/2026
The Door Vacuum Challenge Is the Nemesis of Fire Door Works!.
Just revisited a proiect today and got reminded of the one thing that can bring even the best fire-door setup to its knees door vacuum.
Two Buildings botn Listed. Original external doors (untouchable). Tiny lobby. FD30 internal doors that almost closed... but that last 10mm fought back like a champ.
Classic pressure differential.
The fix ended up being a proper little balancing act:
β’ Intumescent vent installed into the
internal lobby door
β’ Closer adiustments - one sped up, one slowed down
β’ Pressure finally equalised
β’ And now... the door actually closes like it's supposed to whichever way you go in or out.
Amazing how a tiny lobby and a sealed-up listed door can create a mini airlock,
Sometimes it's not the hinges, not the seals, not the closer, it's the building trying to hold its breath.