In-N-Out Electric Ltd

In-N-Out Electric Ltd We’re all about top-tier service. From troubleshooting & panel upgrades to generators & renovations, we do it all with a smile! Ready to power up? Give us a call

We offer fair pricing and quality workmanship with honesty & reliability.

From no lights to a perfect layout with dimmer switch 👌🏽 ✨️ Happy to make your house a home
05/29/2026

From no lights to a perfect layout with dimmer switch 👌🏽 ✨️
Happy to make your house a home

When you update your cellphone, you have piece of mind knowing you're up-to-date  with current technology. Why not updat...
05/18/2026

When you update your cellphone, you have piece of mind knowing you're up-to-date with current technology.

Why not update your electrical panel, to have piece of mind of your families safety?

Hey everyone 👋 It's been a long week of hospital visits & relaxing the hand. I'm sorry to anyone who I maybe missed send...
04/12/2026

Hey everyone 👋

It's been a long week of hospital visits & relaxing the hand. I'm sorry to anyone who I maybe missed sending a message to for rescheduling.

If I missed you, please reach out & I will schedule you in at your convenience

This is only a few items the home inspector "missed". "NMD90 cable must be protected from mechanical damage if it is ins...
03/29/2026

This is only a few items the home inspector "missed".

"NMD90 cable must be protected from mechanical damage if it is installed at a height less than 1.5 m (approx. 5 feet) above the floor"

Luckily enough, the homeowner is having me go through the basement & repair these scary mistakes.

Gimme a shout, I'll be IN-N-OUT
780-838-5843

480V line side of disconnect to main transformer; main 200A disconnect off. I've been having issues with the A phase of ...
02/22/2026

480V line side of disconnect to main transformer; main 200A disconnect off.

I've been having issues with the A phase of a 75kVA 3 phase transformer & when I was doing maintenance & a load test for excessive noise, the wire appeared to have a loose connection; whereas the black & blue were more taught. The expansion & contraction dur to loose connection, caused the lug screw to seize in the lug. I was able to remove the wire by wiggle back & forth by hand!! Luckily enough, at 9:30pm, my customer had a spare disconnect. Replaced the lug with the exact same out of a seperate device. Finished with some de-ox to slow the thermal expansion/contraction of the termination point.

When excessive vibration is present consistently in an area with electrical distribution/ devices, preventative maintenance should be a priority in your electrical system!! Anti-vibration pads under the mounting holes of a compressor & transformer can make a HUGE difference. Unfortunately, the damage is done to the coil of the transformer, but, the problem, with proper maintenance, should never occur again.

Give IN-N-OUT a shout to maintain your electrical system. Whether that may be your home or your work place, allow me to make you feel safe.

780-838-5843

Did you ever get to your place of work in the dead of winter & the lighting was so atrocious you had to bust out the pho...
02/10/2026

Did you ever get to your place of work in the dead of winter & the lighting was so atrocious you had to bust out the phone light?! Give me a call & let me put some light back in your life ✨️
780-838-5843 📱

I mean the conduit is straight.. I mean was...Replaced damaged conduit & ran a 4 wire bx to replace the emt. Flexible, c...
02/01/2026

I mean the conduit is straight.. I mean was...

Replaced damaged conduit & ran a 4 wire bx to replace the emt. Flexible, clean, and done right. Removed all data running through the shop.

Call today to get us working for you, doing it right the first time
780-838-5843

"Let us take the resistance out of your home improvements"

Nice enough weather today, I was able to cut a new recessed box for a GFCI @ the front of a duplex in Prarie Creek. The ...
01/31/2026

Nice enough weather today, I was able to cut a new recessed box for a GFCI @ the front of a duplex in Prarie Creek. The baseboard was pulled off inside (5"or 6" baseboard) & the dedicated circuit was pulled straight to the panel. Realized I couldn't go through the bottom of the panel; main breaker was at the bottom and we cannot pass wire through. Had to come through the top & luckily had a JB with only a transformer!!! I think this turned out perfect!!! Silicone applied to the back of the "in-box" because nobody likes water in their walls... Thankfully, the siding went back without breaking... that was probably the most difficult task!

Clean look; better resale. Don't have someone "slop" the job together with conduit. Do it right the first time!!!!

Call for your 2026 winter items (outside lights/ plugs, trench work, landscape lights, etc) before the snow falls and labor time increases 😄

If your wires are crossed, we’ll help you find your ground
780-838-5843

When you are always there for your customers turned friends.. My heart hurts that they're thinking of leaving, but askin...
01/27/2026

When you are always there for your customers turned friends..
My heart hurts that they're thinking of leaving, but asking me to go down for their electrical needs on their new home... I know I'm doing/ I've done something right ❤️

01/26/2026

I don't see a problem.... they're supposed to get that hot aren't they?

Insulation of the wires was compromised inside. One of the most noticeable smells is plastic burning