It is hard to see but that how glycol concentration is checked. If your chiller uses glycol, its concentration must be c...
10/15/2024

It is hard to see but that how glycol concentration is checked. If your chiller uses glycol, its concentration must be checked at least during every maintenance. Because every chiller has liquid type for which it was designed and if glycol is leaking it can lead to very bad things

Bubbles during leak check are kinda beautiful. After braising it went below 300 microns. Only one little problem, good r...
10/15/2024

Bubbles during leak check are kinda beautiful. After braising it went below 300 microns. Only one little problem, good result I believe

Access to the unit is blocked by garbage. I guess it is more effective than putting a lock…
10/15/2024

Access to the unit is blocked by garbage. I guess it is more effective than putting a lock…

Rewiring harness for the sensor is kinda fun. Especially when guy before you unplugged it without marking where wires we...
10/15/2024

Rewiring harness for the sensor is kinda fun. Especially when guy before you unplugged it without marking where wires went before

Condencer coil cracked and unit was leaking.An interesting case because after new coil was delivered on site, connection...
10/15/2024

Condencer coil cracked and unit was leaking.
An interesting case because after new coil was delivered on site, connection on the new coil was severely damaged. It was necessary to braze aluminum to copper with special rods and only then perform routine work.

Replacing bad VSD. The interesting part was reprogramming because this one is slightly different.
10/15/2024

Replacing bad VSD. The interesting part was reprogramming because this one is slightly different.

Replacing old humidity sensor with a new one. Had to change wiring a little bit.Those sensors have short lifespan of 1-3...
10/15/2024

Replacing old humidity sensor with a new one. Had to change wiring a little bit.
Those sensors have short lifespan of 1-3 years depending on weather conditions.
It is highly recommended to check there operation during every maintenance

It is highly recommended to clean your chiller tubes every 6 months or so. Sometimes simple cleaning can boost efficienc...
10/15/2024

It is highly recommended to clean your chiller tubes every 6 months or so. Sometimes simple cleaning can boost efficiency of a chiller a lot.

Sometimes display on VFD is burned and simple replacement can fix the issue. Instead of buying new VFD…
10/15/2024

Sometimes display on VFD is burned and simple replacement can fix the issue. Instead of buying new VFD…

Proper handling of the unit is vital. In this case, delivering company picked up the unit incorrectly and hit part of it...
10/15/2024

Proper handling of the unit is vital. In this case, delivering company picked up the unit incorrectly and hit part of it. (Warehouse workers said that unit was dragged!).
After such handling, there is a very high possibility that unit got some damage and its performance will be affected. It is possible that part of the structure got internal damage that will reveal itself later.
Visible damage was painted and bended parts were restored