Finac Air-conditioning

Finac Air-conditioning This Is My Official Page
Air-conditioning Solutions Point
Ac Installation
Ac Maintenance

06/08/2026

❄️ Split AC Service in Doha, Qatar πŸ‡ΆπŸ‡¦

Looking for fast and reliable Split AC service in Doha? We provide professional AC maintenance, repair, gas charging, leak testing, installation, and cleaning at affordable prices.

βœ… Split AC Installation
βœ… AC Gas Charging (R410A / R32)
βœ… Gas Leak Detection & Repair
βœ… Indoor & Outdoor Unit Cleaning
βœ… Cooling Problem Solutions
βœ… Emergency AC Repair
βœ… Experienced HVAC Technicians

We serve homes, apartments, villas, offices, and commercial buildings across Doha.

πŸ“ž Contact us today for quick service and affordable prices.

04/08/2026

Hisense Vrf Casset Ac Service In Doha Qatar

03/08/2026

Trane Split AC Outdoor Service Full Details | Gas Checking Step by Step | FINAC Air-conditioning

In this video, I will show the complete Trane Split AC Outdoor Service process from start to finish. This guide is helpful for HVAC technicians, beginners, and anyone who wants to learn professional AC maintenance.

In this video:

- Safety precautions before servicing
- Outdoor unit opening procedure
- Condenser coil cleaning
- Fan motor inspection
- Compressor checking
- Capacitor testing
- Contactor checking
- PCB visual inspection
- Electrical wiring inspection
- Terminal tightening
- Refrigerant pipe inspection
- Suction and discharge pressure checking
- Gas checking with manifold gauge
- Superheat and subcooling basics
- Refrigerant leak inspection
- Operating current (Ampere) checking
- Voltage checking
- Final performance test
- Common Trane outdoor unit problems and solutions
- Professional maintenance tips

This step-by-step tutorial is designed to help you perform outdoor service correctly and improve cooling performance while extending the life of the AC.

Subscribe to FINAC Air-conditioning for more videos on Split AC, VRF, VRV, Cassette AC, Ductable AC, installation, troubleshooting, gas charging, and maintenance.

02/08/2026

Cassette AC Drain Pump Not Working | Full Troubleshooting Guide

Is your Cassette AC drain pump not working? Water leaking from the indoor unit? In this video, FINAC Air-conditioning explains how to diagnose and fix a cassette AC drain pump step by step.

In this video:

- βœ”οΈ Why the drain pump stops working
- βœ”οΈ How to check the drain pump power supply
- βœ”οΈ Float switch testing
- βœ”οΈ Drain pipe blockage checking
- βœ”οΈ Drain pump replacement process
- βœ”οΈ Multimeter testing
- βœ”οΈ Common mistakes to avoid
- βœ”οΈ Final testing after repair

This guide is useful for HVAC technicians, AC service engineers, and beginners working on cassette AC systems.

Like, Share & Subscribe to FINAC Air-conditioning for more HVAC maintenance, VRV, VRF, Split AC, Ductable AC, and Cassette AC troubleshooting videos.

01/08/2026

❄️ FINAC Air-conditioning – AC Maintenance in Qatar πŸ‡ΆπŸ‡¦

Need professional AC maintenance in Qatar?

βœ… Split AC Service
βœ… Ductable AC Service
βœ… Cassette AC Service
βœ… VRF & VRV AC Maintenance
βœ… AC Installation & Repair
βœ… Gas Leak Detection & Gas Charging
βœ… Deep Coil Cleaning
βœ… Electrical & Performance Inspection
βœ… Preventive Maintenance for Homes, Villas & Offices

Why Choose FINAC Air-conditioning?
βœ” Experienced HVAC Technician
βœ” Quality Workmanship
βœ” Fast & Reliable Service
βœ” Service for All Major AC Brands

πŸ“ Serving Doha and across Qatar.

31/07/2026

Trane Split AC Outdoor Service | All Spare Parts Remove & Installation | Full Details Step by Step | FINAC Air-conditioning

In this video, I will show you the complete Trane Split AC Outdoor Unit Service from start to finish. Every spare part will be removed, cleaned, inspected, and reinstalled with proper technician methods.

Video Includes:

- Safety precautions before service
- Power supply isolation
- Outdoor cover removal
- Fan motor removal
- Fan blade removal
- Condenser coil cleaning
- Compressor terminal inspection
- Capacitor checking
- Contactor inspection
- PCB removal and checking
- Pressure switch inspection
- Copper pipe connection checking
- Electrical wiring inspection
- Drain and base tray cleaning
- Full outdoor washing
- Reinstallation of all spare parts
- Final testing
- Voltage, current & gas pressure checking

This video is very helpful for:

- HVAC Technicians
- AC Service Engineers
- Beginners
- Maintenance Staff
- HVAC Students

If you like this video, Like, Share & Subscribe to FINAC Air-conditioning for more professional HVAC maintenance, installation, VRF, VRV, Split AC, Cassette AC, and Ductable AC videos.

:

30/07/2026

Trane Split AC Gas Checking After Service
Complete the service (clean indoor and outdoor units, filters, and condenser coil).
Restore power and run the AC in Cool Mode.
Set the temperature to 16–18Β°C and let it run for 15–20 minutes.
Connect the manifold gauge to the service port.
Measure:
Suction pressure
Discharge pressure (if required)
Check:
Suction line should feel cold.
Liquid line should feel warm.
Measure the air temperature:
Return air temperature
Supply air temperature
A temperature difference of about 8–12Β°C is common for many systems under normal conditions.
Check compressor current with a clamp meter and compare it with the nameplate rating.
Look for signs of low refrigerant:
Low suction pressure
Frost on the evaporator or suction line
Poor cooling
If refrigerant is low:
Find and repair any leak first.
Evacuate the system if it has been opened.
Recharge with the correct refrigerant (such as R410A, R32, or another type specified on the unit nameplate) using the manufacturer's recommended charge.

29/07/2026

Cassette AC Service | Complete Maintenance Guide | Indoor Unit Cleaning Step by Step

In this video, I show the complete Cassette AC service process from start to finish. Learn how to clean the air filter, decorative panel, evaporator coil, blower, drain tray, drain pipe, and drain pump. I also explain how to inspect electrical connections, sensors, PCB, refrigerant pressure, and test the unit after servicing.

This video is helpful for HVAC technicians, AC mechanics, and anyone who wants to learn professional Cassette AC maintenance.

βœ… Air Filter Cleaning
βœ… Evaporator Coil Cleaning
βœ… Blower Cleaning
βœ… Drain Tray & Drain Pipe Cleaning
βœ… Drain Pump Checking
βœ… Electrical Inspection
βœ… Gas Pressure Checking
βœ… Final Cooling Performance Test

Subscribe to FINAC Air-conditioning for more HVAC, VRF, VRV, Split AC, Ductable AC, and Cassette AC service and troubleshooting videos.

27/07/2026

πŸ”§ Carrier Ductable AC Motor Refixing | Full Maintenance Guide πŸ”§

Carrier Ductable AC indoor blower motor installation and refixing should always be done carefully to ensure smooth operation and proper airflow.

βœ… Switch OFF the power supply before starting.
βœ… Remove and inspect the blower motor and wheel.
βœ… Clean dust and dirt from the blower assembly.
βœ… Check motor bearings, shaft, and capacitor.
βœ… Refix the motor correctly and tighten all mounting bolts.
βœ… Align the blower wheel properly to avoid vibration.
βœ… Reconnect wiring as per the wiring diagram.
βœ… Test the unit for airflow, current, noise, and vibration before handing it over.

Proper motor refixing improves cooling performance, reduces noise, and increases the life of the HVAC system.

Follow FINAC Air-conditioning for more HVAC maintenance, VRF, VRV, Split AC, and Ductable AC tips.

12/07/2026

you're making a video on Window AC Service, here's a clear service procedure you can follow:
Window AC Service – Full Process
Turn OFF the power supply.
Remove the front panel and air filter.
Clean the air filter with water and let it dry.
Clean the evaporator coil using a coil cleaner or water.
Clean the blower wheel thoroughly.
Clean the condenser coil from the outdoor side.
Wash the drain tray and ensure the drain hole is not blocked.
Check the fan motor and fan blade condition.
Tighten all electrical connections.
Check the capacitor, thermostat, and wiring.
Measure voltage and running current (ampere).
Inspect for refrigerant (gas) leaks if cooling is low.
Reassemble the unit and restore power.
Test cooling performance and check the outlet air temperature.
Safety Tips:
Always disconnect the power before servicing.
Do not spray water directly on electrical components.
Wear safety gloves and safety glasses.
This service helps improve cooling performance, reduce power consumption, and extend the life of the Window AC.

Address

Patna
Muzaffarpur
843316

Telephone

+918586939019

Website

Alerts

Be the first to know and let us send you an email when Finac Air-conditioning posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Finac Air-conditioning:

Shortcuts

Share