30/06/2026
End of June already! 🤯
Weather has been an interesting one…☀️🥵⛈️
Few call outs to attend to due to the thunderstorms causing power outage to an outbuilding and another causing severe ingress of water damage to the ceiling therefore causing a light fitting to fall down.
In between all that here’s a few jobs carried out,
Distribution board updated complete with new earth rod.
The existing earth rod was severely bent including undersized earth therefore it wasn’t providing a suitable earth to the whole installation.
Amongst testing the property the gas wasn’t bonded and the garage installation wasn’t fused down correctly, all sockets spurred from one socket point. 😬🤦🏻♂️
New sub board installed complete with new supply.
Upgraded florescent lighting to LED improving the quality of light.
Meanwhile elsewhere following on from an EICR, replacement of cooker circuit due to being fused incorrectly including not following manufacturers instructions to wire appliance using HO5/7 flex.
Emergency lighting failed 3 hour battery test including a damaged unit…. All replaced with a few upgraded to twin spot due to covering a large hall area.
Also a shout out to Cards Plus Westbury,
Providing a great service as always for my daughter’s birthday and showing their continued support using me for their electrical needs, thank you! 🙏🏻
For any electrical needs, please do not hesitate to contact me.
As always, happy to help! 😃