ACR Electrical Services I’m a self employed, NICEIC accredited electrician, working in the North London & surrounding areas.

One week, 4 C/Unit changes!! First time using the FuseBox 21-Way dual row fuseboard! CP Electric Ltd
15/01/2023

One week, 4 C/Unit changes!! First time using the FuseBox 21-Way dual row fuseboard! CP Electric Ltd

Removed Halogen/transformer down lights & replaced with Collingwood Lighting Ltd 230v 4.4W warm white integral LED down ...
24/09/2022

Removed Halogen/transformer down lights & replaced with Collingwood Lighting Ltd 230v 4.4W warm white integral LED down lights which are Fire rated & IP rated, as well as fully dimmable, making them perfect for installing in all settings! (Varilight vPro dimmer module installed. One of the best dimmers on the market).
The difference in output from the old to new is literally like night & day. Cannot recommend highly enough…

Consumer unit replacement at a rental property. New 18th edition SPD/RCBO 10-way fusebox. Also installed a new socket ci...
24/09/2022

Consumer unit replacement at a rental property. New 18th edition SPD/RCBO 10-way fusebox. Also installed a new socket circuit with extra sockets in the 2 bedrooms and an Aico Ei3028 Heat/CO detector in the Kitchen & an Aico Ei3016 optical smoke alarm in the Hallway so the property is now fully protected!
CP Electric Ltd Aico

Shed Office install in St. Albans, 6mm 3-core SWA clipped around the fence and terminated in an IP rated wiska box. 4 so...
28/05/2022

Shed Office install in St. Albans, 6mm 3-core SWA clipped around the fence and terminated in an IP rated wiska box. 4 sockets, 4 lights inside & 2 outside lights on a fob controlled lighting system.



Same job as the 60 year fusebox. This was in the brick built shed, wrong size cable/fuses running the garage, power, lig...
13/02/2022

Same job as the 60 year fusebox. This was in the brick built shed, wrong size cable/fuses running the garage, power, lighting and an old electric hob/cooker!
All removed and replaced with a 4-way FuseBox mini mcb consumer unit backed up in the main consumer unit by the appropriate RCBO protection.

Extremely old fuse board with BS 88 & BS 1361 miniture fuses used for each circuit. I’d guess this was installed around ...
13/02/2022

Extremely old fuse board with BS 88 & BS 1361 miniture fuses used for each circuit. I’d guess this was installed around 60 years ago and although still going strong was obviously not up to the current regs & standards! Replaced & tidied up with a 10 way FuseBox 18th edition consumer unit with individual RCBO protection to all circuits & Type 2 Surge Protection Device.

Another   consumer unit replacement.The original fuseboard was around 50 years old and the neutral screw on the load sid...
24/12/2021

Another consumer unit replacement.
The original fuseboard was around 50 years old and the neutral screw on the load side of the main isolator had become loose and so began to arc. Over time this could have led to a fire which the Fire Brigade say is one of the most common electical fires they have to attend to (the other being from poorly installed down lights).

A local garden lighting installation carried out recently. All switched via a fob lighting system.
02/12/2021

A local garden lighting installation carried out recently. All switched via a fob lighting system.

The new inline splice wago connectors making life slightly easier for Sparkies connecting up lights and other inline con...
21/11/2021

The new inline splice wago connectors making life slightly easier for Sparkies connecting up lights and other inline connections…

Recently discovered during an EICR on a house. The client had had the downlights replaced 6 months ago so the work shoul...
21/11/2021

Recently discovered during an EICR on a house. The client had had the downlights replaced 6 months ago so the work should have been carried out to the latest regs but none of the CPC’s (earths) were connected at the junction boxes or the light fittings which are all metal and not double insulated, they’d even used the original white T&E cable to save themselves the time & cost of replacing a 12” strip!
Glad to say all lights & JB’s are now fully “earthed” up and safe!!

FuseBox Thursday!! These tight spaces are doing wonders for my back…😂🧐
18/11/2021

FuseBox Thursday!! These tight spaces are doing wonders for my back…
😂🧐

Address

London

Opening Hours

Monday 8am - 4pm
Tuesday 8am - 4pm
Wednesday 8am - 4pm
Thursday 8am - 4pm
Friday 8am - 4pm

Telephone

+447921159640

Website

Alerts

Be the first to know and let us send you an email when ACR Electrical Services posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to ACR Electrical Services:

Featured

Share