Kali Electrics

Kali Electrics ⚡️Fully qualified Electrician
📍London based
💬 Contact us on 07542607865 for enquiries
‼️Emergency call out services available

Client needed their lighting circuits rewired and second fixed on short notice. We stepped in and completed the job in a...
25/04/2025

Client needed their lighting circuits rewired and second fixed on short notice. We stepped in and completed the job in a single day with a solid 12-hour shift. Another project completed and another happy client!

Landlords & homeowners, did you know an EICR is a legal requirement? Make sure your property is up to code! 📋✅🔌 Need an ...
22/03/2025

Landlords & homeowners, did you know an EICR is a legal requirement? Make sure your property is up to code! 📋✅

🔌 Need an Electrician? Get in Touch with Kali Electrics Ltd! ⚡

Looking for reliable electrical services? Whether it’s an EICR inspection, installations, repairs, or maintenance, we've got you covered! ✅

📞 Call us: 07542607865
📧 Email us: [email protected]
🌍 Visit our website: www.kalielectrics.co.uk
📲 Follow us: .electrics

Your safety is our priority! Contact us today for expert electrical solutions. 💡⚡



🔧 Another Quality Consumer Board Upgrade by Kali Electrics! 🔧✔ New RCD-protected board for enhanced safety✔ Hardwired sm...
21/03/2025

🔧 Another Quality Consumer Board Upgrade by Kali Electrics! 🔧

✔ New RCD-protected board for enhanced safety
✔ Hardwired smoke alarm with wireless interlink to heat alarm
✔ New bonding installed for full compliance
✔ Additional double sockets installed throughout the property

🏡 Landlord trusts our work 100% and has handed over the keys! 🏡

Looking for a reliable electrician? Contact us today for top-quality electrical services! ⚡🔌

Replaced these non-IP-rated halogen bathroom lights with the correct IP-rated downlights. The old ones were a fire hazar...
20/03/2025

Replaced these non-IP-rated halogen bathroom lights with the correct IP-rated downlights. The old ones were a fire hazard and not waterproof—definitely not suitable for a bathroom! A reminder to always use the right fittings and hire professionals to get the job done safely and correctly. In this case, the landlord had the tenant install them, which led to the wrong type being used and a failed EICR inspection. Don’t cut corners when it comes to electrical safety

Upgraded the consumer unit to meet the latest regulations! The old board wasn’t fire-rated, so we ensured full complianc...
16/03/2025

Upgraded the consumer unit to meet the latest regulations! The old board wasn’t fire-rated, so we ensured full compliance with fire safety standards. Fire exits are now properly protected, enhancing overall safety. Another step towards a safer and more secure installation!

Newly installed consumer unit featuring all-new RCBOs and SPD, fully compliant with the latest electrical safety regulat...
13/03/2025

Newly installed consumer unit featuring all-new RCBOs and SPD, fully compliant with the latest electrical safety regulations. Prioritizing safety, reliability, and future-proofing every installation

Quick and clean board change—done right. Some of these tools on display have been with me for over 10 years. Quality too...
11/03/2025

Quick and clean board change—done right. Some of these tools on display have been with me for over 10 years. Quality tools make all the difference.

During the Electrical Installation Condition Report (EICR), several concerning issues were found with the oven and cooke...
11/03/2025

During the Electrical Installation Condition Report (EICR), several concerning issues were found with the oven and cooker installation. The landlord was informed promptly, with supporting pictures and guidance on the correct installation procedures. The appliances should be connected using heat-resistant flex cable and properly installed with two separate cooker outlet points to comply with current electrical safety standards

The existing consumer unit is outdated and no longer meets current electrical regulations. It was installed several year...
11/03/2025

The existing consumer unit is outdated and no longer meets current electrical regulations. It was installed several years ago and now requires an upgrade to comply with modern safety standards. The landlord recently purchased the property and identified the need for several electrical improvements, including replacing the consumer unit to ensure compliance with current regulations

I was called out to investigate a loss of power. Upon inspection, I discovered that the installation was in a highly dan...
09/03/2025

I was called out to investigate a loss of power. Upon inspection, I discovered that the installation was in a highly dangerous condition. The main 60A fuse had been improperly bypassed using a thin strand of copper wire, which poses a severe fire and electrocution risk. This makeshift connection not only compromises the circuit’s protective function but also increases the likelihood of overheating and catastrophic failure. The installation was immediately deemed unsafe, and appropriate isolation and reporting measures were taken to prevent any further risk.

New kitchen lights installation for this happy customer ⚡️😊
09/03/2025

New kitchen lights installation for this happy customer ⚡️😊

⚡️Fully qualified⚡️NAPIT registered ⚡️Experience in domestic and commercial properties. 📍Covering all areas of London📞Co...
08/03/2025

⚡️Fully qualified
⚡️NAPIT registered
⚡️Experience in domestic and commercial properties.
📍Covering all areas of London
📞Contact us for enquiries

Address

London

Alerts

Be the first to know and let us send you an email when Kali Electrics posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Featured

Share

Category