Birds nesting on a roof can cause all kinds of issues, especially if they are nesting around an outlet on a flat roof.As...
18/09/2021

Birds nesting on a roof can cause all kinds of issues, especially if they are nesting around an outlet on a flat roof.

As you can see from the photos we took during an inspection, the debris left by the birds such as small bones, leaves twigs and other debris had caused a major blockage on the outlet. This led to leaks around the adjacent flashings and vents as the water was not able to escape.

If you would like to book a flat roof inspection, please call us today on 020 8037 1848.

Before & after photos showing a neglected felt roof which was in dire need of replacement.We replaced the roof with a si...
17/09/2021

Before & after photos showing a neglected felt roof which was in dire need of replacement.

We replaced the roof with a single ply Sika-Trocal system which comes with a 20 year manufacturer backed guarantee.

Get in touch today for a no obligation quotation 020 8037 1848

Another Sika-Trocal roof completed for a college in Orpington.
17/09/2021

Another Sika-Trocal roof completed for a college in Orpington.

Never undermine the damage that moss can cause to valleys and tiled roofs in general.We carried out an assessment recent...
16/09/2021

Never undermine the damage that moss can cause to valleys and tiled roofs in general.

We carried out an assessment recently where there was a large build-up of moss on our clients roof valleys. This had resulted in water breaching the cement verges on either side of the valley, causing water ingress.

Removal of the moss and re-pointing of the verges was recommended to the client.

A clear indication of capillary action on these asbestos cement sheets on a commercial building in South London.  The gr...
16/09/2021

A clear indication of capillary action on these asbestos cement sheets on a commercial building in South London.

The green marks around the filler on the pan of each sheet is a good indicator that water is tracking on the underside of the sheet and causing water ingress internally. There is also a large void between the poorly installed box gutter and the original upstand.