Xiongli HVAC

Xiongli HVAC Contact information, map and directions, contact form, opening hours, services, ratings, photos, videos and announcements from Xiongli HVAC, Heating, ventilating & air conditioning service, No. 12, North Gaogui Avenue, Xingtan Town, Foshan.

Professional air conditioning terminal product manufacturer, suitable for all kinds of large-scale construction projects, airports, exhibition halls, subway stations, hotels, shopping malls, villas, residences and other fields.

Another batch of high-performance box fans has been shipped!
09/09/2026

Another batch of high-performance box fans has been shipped!

25/08/2026
23/08/2026

Here is the English breakdown of axial fan testing, core features, and primary applications based on the factory testing process:

I. Core Testing Items for Axial Fans

● Operation & Direction Check: Verifies motor wiring and power supply phase alignment to ensure the impeller rotates in the direction indicated by the airflow arrow, checking for smooth startup/shutdown without binding or noise.
● Dynamic Balance & Vibration Test: Monitors vibration amplitudes at the casing and bearing points during high-speed rotation using vibration meters to prevent shaking or bolt loosening caused by imbalance.
● Airflow & Static Pressure Performance Test: Measures volumetric airflow rate (CFM / m^3/h) and static pressure (Pa) in a standardized test duct to verify compliance with design ratings.
● Electrical & Motor Temperature Rise Test: Measures operating current, voltage, and power input under rated loads to prevent motor overload, while tracking winding and bearing temperatures.
● Noise Level Measurement: Measures aerodynamic and mechanical noise levels (dB) at specified distances using sound level meters to ensure compliance with environmental acoustics standards.
II. Key Features & Primary Applications

Key Features

● High Airflow / Low Static Pressure: Operates with propeller-style blades to move large volumes of air quickly against low system resistance.
● Straight-Through Airflow: Parallel inlet and outlet paths align airflow directly along the motor axis with minimal internal resistance.
● Compact & Easy Installation: Cylindrical casing allows direct mounting on building walls or inline within ventilation ducts without requiring extra floor space.
Primary Applications

● Large Area Ventilation: General air exchange across industrial workshops, agricultural greenhouses, and livestock facilities.
● Duct Boosting & Exhaust: Short-distance inline duct pressure boosting and stairwell pressurization for fire safety.
● Equipment Cooling: Forced-air cooling in cooling towers, large power generators, and heavy industrial machinery. Meera चीन की मीरा

22/08/2026

A batch of axial fans with 80,000 air volume will be shipped after passing the test.

22/08/2026

The axial fan with an air volume of 80,000 is being tested Lee Pace

Customers go to the factory to inspect the goods, test the performance of the fan, and the wind is strong. Lee Pace
22/08/2026

Customers go to the factory to inspect the goods, test the performance of the fan, and the wind is strong. Lee Pace

Axial Fans: Features & ApplicationsKey Features● High Volume, Low Pressure: Generates high airflow rates at relatively l...
22/08/2026

Axial Fans: Features & Applications

Key Features

● High Volume, Low Pressure: Generates high airflow rates at relatively low static pressures.
● Straight-Through Airflow: Parallel inlet and outlet maintain continuous linear airflow with minimal internal resistance.
● Compact Footprint: Mounts directly within duct networks or building walls without requiring extra mechanical floor Lee Pace

The key differences, features, and applications between axial fans and centrifugal fans highlight their distinct perform...
22/08/2026

The key differences, features, and applications between axial fans and centrifugal fans highlight their distinct performance characteristics:

Comparison Dimension
Axial Fan
Centrifugal Fan
Appearance & Structure
Cylindrical casing with impeller and motor on the same axis
Scroll-shaped housing or square cabinet enclosure, driven by belt pulley or direct coupling
Airflow Direction
Axial in, axial out (parallel to the rotational axis)
Axial in, radial out (90° perpendicular turn)
Airflow vs. Pressure
High airflow / Low static pressure
High static pressure / Medium to high airflow
System Resistance
Best for low-resistance, short-duct, or un-ducted systems
Designed to overcome high resistance from long duct runs, filters, and complex ductwork
Space & Installation
Compact and lightweight; can be installed directly inside ducts or on wall cutouts
Larger footprint; usually requires dedicated mechanical rooms or floor bases

Address

No. 12, North Gaogui Avenue, Xingtan Town
Foshan
528325

Website

Alerts

Be the first to know and let us send you an email when Xiongli HVAC posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Shortcuts

Share